العنوان: Determination of Benzimidazoles in Chicken and Egg Samples by Urea-Based Covalent Organic Polymer (UCOP) Pipette Tip–Solid-Phase Extraction (PT–SPE) and High-Performance Liquid Chromatography–Tandem Mass Spectrometry (HPLC–MS).
المؤلفون: Xiang, Jian Jun, Yuan, Li-Juan, Liao, Qie Gen, Zhang, Da Wen, Luo, Lin Guang
المصدر: Analytical Letters; 2024, Vol. 57 Issue 8, p1215-1226, 12p
مصطلحات موضوعية: LIQUID chromatography-mass spectrometry, FOURIER transform infrared spectroscopy, POLYMERS, PIPETTES, SCANNING electron microscopy, BENZIMIDAZOLES
مستخلص: A urea-based covalent organic polymer (UCOP), was synthesized using 1,4-phenylene diisocyanate (PPDI) and 4,4′,4″-(1,3,5-triazine-2,4,6-triyl) trianiline (TTTA) and characterized by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and nitrogen adsorption-desorption isotherm analysis. The prepared material was employed as an adsorbent for pipette tip–solid-phase extraction (PT–SPE) for benzimidazoles before high-performance liquid chromatography–tandem mass spectrometry analysis (HPLC–MS). The parameters affecting the isolation efficiency, including salt concentration, sample pH, mass of adsorbent, and types and volumes of eluent, were optimized. Using these conditions, PT–SPE provided good linearity from 0.1 to 10 μg kg−1 with low limits of detections (LODs) of 0.02 μg kg−1 together with good precision (relative standard deviations from 4.2 to 8.3%) and accuracy (recoveries from 76.2 to 84.8%). The results demonstrate that the urea-based covalent organic polymer has the potential for the enrichment of trace benzimidazoles. [ABSTRACT FROM AUTHOR]
Copyright of Analytical Letters is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:00032719
DOI:10.1080/00032719.2023.2244621