Pop-up Langmuir probe diagnostic in the water cooled divertor of Wendelstein 7-X.

التفاصيل البيبلوغرافية
العنوان: Pop-up Langmuir probe diagnostic in the water cooled divertor of Wendelstein 7-X.
المؤلفون: Pandey, A., Bohm, S., Carls, A., Cordes, C., Endler, M., Fellinger, J., Freundt, S., Gallowski, K., Hammond, K., Hathiramani, D., Isberner, G., Kallmeyer, J. P., Krause, M., Kügler, J., Otte, M., Pedersen, T. S., Rondeshagen, D., Ruhnau, J., Schröder, T., Sieber, T.
المصدر: Review of Scientific Instruments; Apr2024, Vol. 95 Issue 4, p1-21, 21p
مصطلحات موضوعية: LANGMUIR probes, BRIDGE circuits, MAGNETIC flux, ELECTRONIC circuits, MAGNETIC fields, FUSION reactor divertors, STELLARATORS
مستخلص: The design, development, and successful implementation of pop-up Langmuir probes installed in the water-cooled divertor of W7-X are described. The probes are controlled by drive coils (actuators) installed behind the divertor plates. These drive coils make use of the magnetic field in W7-X to move the probe tips into and out of the plasma. The drive coils were installed in the vacuum vessel after extensively testing the durability of the coils and analyzing the criteria for safe operation. The probe design is carefully tailored for each of the 36 probe tips in order to be suitable for the different magnetic field configurations used in W7-X and ensure that the probes do not present leading edges to the magnetic flux tubes. An electronic bridge circuit is used for measurement to compensate for the effects of signal propagation time on the long cable lengths used. The diagnostic is integrated with the segment control of W7-X for automated operation and control of the diagnostic. The evaluation of the results from the plasma operation is presented after accounting for appropriate sheath expansion for negative bias voltage on the probes. [ABSTRACT FROM AUTHOR]
Copyright of Review of Scientific Instruments is the property of American Institute of Physics and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:00346748
DOI:10.1063/5.0188738