Automated expert-level scleral spur detection and quantitative biometric analysis on the ANTERION anterior segment OCT system.

التفاصيل البيبلوغرافية
العنوان: Automated expert-level scleral spur detection and quantitative biometric analysis on the ANTERION anterior segment OCT system.
المؤلفون: Bolo, Kyle, Aroca, Galo Apolo, Pardeshi, Anmol A., Chiang, Michael, Burkemper, Bruce, Xiaobin Xie, Huang, Alex S., Simonovsky, Martin, Xu, Benjamin Y.
المصدر: British Journal of Ophthalmology; May2024, Vol. 108 Issue 5, p702-709, 8p
مستخلص: Aim To perform an independent validation of deep learning (DL) algorithms for automated scleral spur detection and measurement of scleral spur-based biometric parameters in anterior segment optical coherence tomography (AS-OCT) images. Methods Patients receiving routine eye care underwent AS-OCT imaging using the ANTERION OCT system (Heidelberg Engineering, Heidelberg, Germany). Scleral spur locations were marked by three human graders (reference, expert and novice) and predicted using DL algorithms developed by Heidelberg Engineering that prioritise a false positive rate <4% (FPR4) or true positive rate >95% (TPR95). Performance of human graders and DL algorithms were evaluated based on agreement of scleral spur locations and biometric measurements with the reference grader. Results 1308 AS-OCT images were obtained from 117 participants. Median differences in scleral spur locations from reference locations were significantly smaller (p<0.001) for the FPR4 (52.6±48.6 μm) and TPR95 (55.5±50.6 μm) algorithms compared with the expert (61.1±65.7 μm) and novice (79.4±74.9 μm) graders. Intergrader reproducibility of biometric measurements was excellent overall for all four (intraclass correlation coefficient range 0.918-0.997). Intergrader reproducibility of the expert grader (0.567-0.965) and DL algorithms (0.746-0.979) exceeded that of the novice grader (0.146-0.929) for images with narrow angles defined by OCT measurement of angle opening distance 500 μm anterior to the scleral spur (AOD500)<150 μm. Conclusions DL algorithms on the ANTERION approximate expert-level measurement of scleral spur-based biometric parameters in an independent patient population. These algorithms could enhance clinical utility of AS-OCT imaging, especially for evaluating patients with angle closure and performing intraocular lens calculations. [ABSTRACT FROM AUTHOR]
Copyright of British Journal of Ophthalmology is the property of BMJ Publishing Group and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:00071161
DOI:10.1136/bjo-2022-322328