دورية أكاديمية

Silicon extraction from x-ray amorphous soil constituents: a method comparison of alkaline extracting agents.

التفاصيل البيبلوغرافية
العنوان: Silicon extraction from x-ray amorphous soil constituents: a method comparison of alkaline extracting agents.
المؤلفون: Stein, Mathias, Puppe, Daniel, Kaczorek, Danuta, Buhtz, Christian, Schaller, Jörg
المصدر: Frontiers in Environmental Science; 2024, p1-9, 9p
مصطلحات موضوعية: SOIL science, INDUCTIVELY coupled plasma atomic emission spectrometry, SOIL ecology, MICROWAVE plasmas, SILICA, IRON
مستخلص: The growing interest in amorphous silica (ASi) within the fields of soil science and ecology underscores the necessity for a reliable protocol to estimate ASi contents in soil. Alkaline wet chemical extraction methods are commonly employed for silicon (Si) extraction fromoperationally defined (x-ray) amorphous Si phases or short-range ordered mineral phases in soils and marine sediments. In our study we conducted a comparative analysis of four alkaline extraction methods (1% sodium carbonate, 0.5M sodium carbonate, 0.2M sodium hydroxide, and 0.1M Tiron), assessing their extraction selectivity as well as effectiveness using soils artificially enriched with varying, defined amounts of ASi. While extraction effectiveness was evaluated by determining the recovery rate of initially added ASi, extraction selectivity was determined by measuring aluminum (Al) and iron (Fe) concentrations as indicators of the dissolution of non-target mineral phases. Microwave plasma atom emission spectrometry was used to analyze Al, Fe, and Si concentrations in the extracts. Our results indicate that extraction with 0.2M sodium hydroxide yields the best outcomes in terms of both extraction effectiveness and selectivity. Thismore recent extraction technique is conducted at the most alkaline pH (13.3) of all four methods tested, but at ambient temperature (21°C) decreasing the dissolution of non-target mineral phases. Though, no wet-chemical extraction used on heterogeneous samples like soil is precisely selective, and thus able to quantify the target analyte only. Hence, data obtained by such procedures still need to be interpreted with caution considering all their limitations. [ABSTRACT FROM AUTHOR]
Copyright of Frontiers in Environmental Science is the property of Frontiers Media S.A. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:2296665X
DOI:10.3389/fenvs.2024.1389022