دورية أكاديمية

Self‐Powered Biomimetic Pressure Sensor Based on Mn–Ag Electrochemical Reaction for Monitoring Rehabilitation Training of Athletes.

التفاصيل البيبلوغرافية
العنوان: Self‐Powered Biomimetic Pressure Sensor Based on Mn–Ag Electrochemical Reaction for Monitoring Rehabilitation Training of Athletes.
المؤلفون: Yang, Ziyan, Wang, Qingzhou, Yu, Huixin, Xu, Qing, Li, Yuanyue, Cao, Minghui, Dhakal, Rajendra, Li, Yang, Yao, Zhao
المصدر: Advanced Science; 7/3/2024, Vol. 11 Issue 25, p1-11, 11p
مصطلحات موضوعية: PRESSURE sensors, ATHLETE training, INFORMATION display systems, WEARABLE technology, PIEZOELECTRIC detectors, MACHINE learning, LIGHT emitting diodes, POTENTIOMETRY
مستخلص: Self‐powered pressure detection using smart wearable devices is the subject of intense research attention, which is intended to address the critical need for prolonged and uninterrupted operations. Current piezoelectric and triboelectric sensors well respond to dynamic stimuli while overlooking static stimuli. This study proposes a dual‐response potentiometric pressure sensor that responds to both dynamic and static stimuli. The proposed sensor utilizes interdigital electrodes with MnO2/carbon/polyvinyl alcohol (PVA) as the cathode and conductive silver paste as the anode. The electrolyte layer incorporates a mixed hydrogel of PVA and phosphoric acid. The optimized interdigital electrodes and sandpaper‐like microstructured surface of the hydrogel electrolyte contribute to enhanced performance by facilitating an increased contact area between the electrolyte and electrodes. The sensor features an open‐circuit voltage of 0.927 V, a short‐circuit current of 6 µA, a higher sensitivity of 14 mV/kPa, and outstanding cycling performance (>5000 cycles). It can accurately recognize letter writing and enable capacitor charging and LED lighting. Additionally, a data acquisition and display system employing the proposed sensor, which facilitates the monitoring of athletes' rehabilitation training, and machine learning algorithms that effectively guide rehabilitation actions are presented. This study offers novel solutions for the future development of smart wearable devices. [ABSTRACT FROM AUTHOR]
Copyright of Advanced Science is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:21983844
DOI:10.1002/advs.202401515