دورية أكاديمية

Synthesis of gadolinium‐enhanced glioma images on multisequence magnetic resonance images using contrastive learning.

التفاصيل البيبلوغرافية
العنوان: Synthesis of gadolinium‐enhanced glioma images on multisequence magnetic resonance images using contrastive learning.
المؤلفون: Xie, Qian, Lin, Yusong, Wang, Meiyun, Wu, Yaping
المصدر: Medical Physics; Jul2024, Vol. 51 Issue 7, p4888-4897, 10p
مصطلحات موضوعية: MAGNETIC resonance imaging, GLIOMAS, CONTRAST media, GENERATIVE adversarial networks, SIGNAL-to-noise ratio, TOTAL body irradiation
مستخلص: Background: Gadolinium‐based contrast agents are commonly used in brain magnetic resonance imaging (MRI), however, they cannot be used by patients with allergic reactions or poor renal function. For long‐term follow‐up patients, gadolinium deposition in the body can cause nephrogenic systemic fibrosis and other potential risks. Purpose: Developing a new method of enhanced image synthesis based on the advantages of multisequence MRI has important clinical value for these patients. In this paper, an end‐to‐end synthesis model structure similarity index measure (SSIM)‐based Dual Constrastive Learning with Attention (SDACL) based on contrastive learning is proposed to synthesize contrast‐enhanced T1 (T1ce) using three unenhanced MRI images of T1, T2, and Flair in patients with glioma. Methods: The model uses the attention–dilation generator to enlarge the receptive field by expanding the residual blocks and to strengthen the feature representation and context learning of multisequence MRI. To enhance the detail and texture performance of the imaged tumor area, a comprehensive loss function combining patch‐level contrast loss and structural similarity loss is created, which can effectively suppress noise and ensure the consistency of synthesized images and real images. Results: The normalized root‐mean‐square error (NRMSE), peak signal‐to‐noise ratio (PSNR), and SSIM of the model on the independent test set are 0.307 ±$\pm$ 0.12, 23.337 ±$\pm$ 3.21, and 0.881 ±$\pm$ 0.05, respectively. Conclusions: Results show this method can be used for the multisequence synthesis of T1ce images, which can provide valuable information for clinical diagnosis. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:00942405
DOI:10.1002/mp.17004