دورية أكاديمية

Microphysiological system with integrated sensors to study the effect of pulsed electric field.

التفاصيل البيبلوغرافية
العنوان: Microphysiological system with integrated sensors to study the effect of pulsed electric field.
المؤلفون: Bakute, Neringa, Andriukonis, Eivydas, Kasperaviciute, Kamile, Dobilas, Jorunas, Sapurov, Martynas, Mozolevskis, Gatis, Stirke, Arunas
المصدر: Scientific Reports; 8/12/2024, Vol. 14 Issue 1, p1-12, 12p
مصطلحات موضوعية: MICROPHYSIOLOGICAL systems, ELECTRIC field effects, SOFT lithography, ELECTRIC fields, CELL permeability
مستخلص: This study focuses on the use of pulsed electric fields (PEF) in microfluidics for controlled cell studies. The commonly used material for soft lithography, polydimethylsiloxane (PDMS), does not fully ensure the necessary chemical and mechanical resistance in these systems. Integration of specific analytical measurement setups into microphysiological systems (MPS) are also challenging. We present an off-stoichiometry thiol-ene (OSTE)-based microchip, containing integrated electrodes for PEF and transepithelial electrical resistance (TEER) measurement and the equipment to monitor pH and oxygen concentration in situ. The effectiveness of the MPS was empirically demonstrated through PEF treatment of the C6 cells. The effects of PEF treatment on cell viability and permeability to the fluorescent dye DapI were tested in two modes: stop flow and continuous flow. The maximum permeability was achieved at 1.8 kV/cm with 16 pulses in stop flow mode and 64 pulses per cell in continuous flow mode, without compromising cell viability. Two integrated sensors detected changes in oxygen concentration before and after the PEF treatment, and the pH shifted towards alkalinity following PEF treatment. Therefore, our proof-of-concept technology serves as an MPS for PEF treatment of mammalian cells, enabling in situ physiological monitoring. [ABSTRACT FROM AUTHOR]
Copyright of Scientific Reports is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:20452322
DOI:10.1038/s41598-024-69693-w