A Correction Formula for the Real Intraocular Pressure After LASIK for the Correction of Myopic Astigmatism.

التفاصيل البيبلوغرافية
العنوان: A Correction Formula for the Real Intraocular Pressure After LASIK for the Correction of Myopic Astigmatism.
المؤلفون: Kohlhaas, Markus, Spoerl, Eberhard, Boehm, Andreas G., Pollack, Katharina
المصدر: Journal of Refractive Surgery; Mar2006, Vol. 22 Issue 3, p263-267, 5p
مصطلحات موضوعية: ASTIGMATISM, REFRACTIVE errors, LASIK, CORNEA laser surgery, MEDICAL research
مستخلص: PURPOSE: To create a correction formula to determine the real intraocular pressure (IOP) after LASIK considering the altered corneal thickness, corneal curvature, and corneal stability. METHODS: This prospective clinical trial comprised 101 eyes of 59 patients (34 women and 25 men) that underwent LASIK with a mean preoperative spherical equivalent refraction of -6.3±2.17 diopters (D) (-3.0 to -11.5 D). Mean patient age was 32±9 years. Preoperatively and 6 months postoperatively, IOP (by Goldmann applanation tonometry), keratometry (by topography), and central corneal thickness (CCT) (by ultrasound pachymetry) were evaluated. These parameters were measured in all patients between 8 and 11 o'clock in the morning. RESULTS: Due to the LASIK procedure, IOP was reduced from 16.5±2.1 mmHg (range: 12 to 22 mmHg) to 12.9±1.9 mmHg (range: 8 to 16 mmHg). Multiple linear regression analysis of the IOP values before and after LASIK showed a significant correlation between the measured IOP and CCT and keratometry values (R²=0.631; P<.001). After LASIK, the biomechanical bending strength of the cornea is reduced by the cut so that the measured IOP must be additionally corrected by 0.75 mmHg. An equation containing all three changes is given: IOP (real) = IOP (measured) - (540-CCT)/71 + (43 - K-value)/2.7 + 0.75 mmHg. CONCLUSIONS: Intraocular pressure measurements after LASIK for the correction of myopia are inaccurate as a consequence of changes in CCT, corneal curvature, and corneal flap stability. After LASIK, the measured IOP should be corrected to avoid false low IOP applanation readings. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Refractive Surgery is the property of SLACK Incorporated and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:1081597X
DOI:10.3928/1081-597X-20060301-11