Use of an automated device for alternative site blood glucose monitoring.

التفاصيل البيبلوغرافية
العنوان: Use of an automated device for alternative site blood glucose monitoring.
المؤلفون: Fineberg, S. Edwin, Bergenstal, Richard M., Bernstein, Robert M., Laffel, Lori M., Schwartz, Sherwyn L., Fineberg, S E, Bergenstal, R M, Bernstein, R M, Laffel, L M, Schwartz, S L
المصدر: Diabetes Care; Jul2001, Vol. 24 Issue 7, p1217-1220, 4p, 1 Color Photograph, 1 Diagram, 1 Graph
مصطلحات موضوعية: BLOOD sugar monitors, BLOOD sugar analysis, MEDICAL equipment, AUTOMATION, BLOOD collection, BLOOD sugar monitoring, COMPARATIVE studies, ELECTROCHEMISTRY, TYPE 1 diabetes, RESEARCH methodology, MEDICAL cooperation, TYPE 2 diabetes, REGRESSION analysis, RESEARCH, RESEARCH evaluation, PRODUCT design, EVALUATION research, EQUIPMENT & supplies
مستخلص: Objective: To evaluate the accuracy, comfort, and ease of use of a new automated device for blood glucose monitoring using the arm as an alternative sampling site.Research Design and Methods: These studies use an automated hand-held device that applies a small vacuum, lances the skin, transfers blood onto an electrochemical test strip, and measures glucose. Patients who had type 1 or type 2 diabetes and had received no prior training using this device were recruited from five diabetes clinics. Testing was performed by the patients using this device and by trained healthcare professionals. Blood glucose was measured by 354 patients: from the arm using the device, from the finger using a laboratory reference instrument, and from the finger using the device via the secondary test port. Each patient completed a questionnaire rating the level of pain and ease of use of the device.Results: Blood glucose results in samples obtained from the arm with the automated device agreed well with finger-stick plasma glucose results using a reference instrument (regression slope 0.98, intercept 0.01 mmol/l [0.1 mg/dl], r = 0.96). Error grid analysis showed that 100% of the measurements fell within zones A and B. In the survey, 60% of the patients reported that arm testing with the automated device was "painless;" another 31% of the patients stated that it was "much less painful," and 6% of patients considered using the device "less painful" than finger-stick testing. In a survey containing 15 questions for rating the ease of use with a scale of 1 to 6, the overall mean rating was 5.5.Conclusions: The automated device is easy to use and provides accurate glucose results; 97% of the patients found it less painful than finger-stick testing. [ABSTRACT FROM AUTHOR]
Copyright of Diabetes Care is the property of American Diabetes Association and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:01495992
DOI:10.2337/diacare.24.7.1217