العنوان: Computed tomography versus aortography in diagnosis of aortic dissection.
المؤلفون: Parienty, Roger, Couffinhal, Jean-Claude, Wellers, Michel, Farge, Claude, Pradel, Janine, Dologa, Mike, Parienty, R A, Couffinhal, J C, Wellers, M, Farge, C, Pradel, J, Dologa, M
المصدر: CardioVascular & Interventional Radiology; Dec1982, Vol. 5 Issue 6, p285-291, 7p
مصطلحات موضوعية: ANGIOGRAPHY, AORTIC aneurysms, COMPARATIVE studies, COMPUTED tomography, RESEARCH methodology, MEDICAL cooperation, RESEARCH, EVALUATION research, DISSECTING aneurysms
مستخلص: The use of computed tomography (CT) versus aortography is evaluated in a limited study of 17 cases of aortic dissection (AD). With the constraints of the present state of the technology and lack of availability of CT scanners at some centers, aortography remains the premier and often the only diagnostic test to choose in an emergency. CT, however, may be an asset in the diagnosis of AD when: (1) atypical or misleading clinical presentations are evident that do not require aortography; (2) aortography is contraindicated in a weakened patient, when there is no emergency; (3) aortography is a risk while there is a strong suggestion of AD; (4) patency of a false channel must be confirmed. These circumstances were encountered in five patients. In addition, a localized infrarenal AD was fortuitously discovered in two patients presenting with abdominal visceral cancer. On patient follow-up, CT is less invasive and may be performed in asymptomatic patients undergoing treatment, thereby facilitating the early detection of complications. Detailed computed tomograms often yield superior diagnostic information only if the CT study includes rapid sequential scans immediately following a fast intravenous bolus of contrast material. [ABSTRACT FROM AUTHOR]
Copyright of CardioVascular & Interventional Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:01741551
DOI:10.1007/BF02552799