Unreliability of EDTA samples for measuring bioamine neurotransmitter levels in cats.

التفاصيل البيبلوغرافية
العنوان: Unreliability of EDTA samples for measuring bioamine neurotransmitter levels in cats.
المؤلفون: Ramos, Daniela, Reche-Junior, Archivaldo, Brandão, Juliana Dinéia Perez, Arita, Danielle Yuri, Casarini, Dulce Elena, Mills, Daniel S
المصدر: Journal of Feline Medicine & Surgery; Feb2021, Vol. 23 Issue 2, p190-193, 4p
مستخلص: Objectives: The aim of this study was to assess the reliability of an EDTA-based method for measuring cat blood bioamines. Methods: Test 1 involved collecting blood samples from seven university laboratory cats. The samples were transferred to EDTA, heparin and plain tubes to determine concentrations of four bioamines (serotonin, dopamine, epinephrine [adrenaline] and norepinephrine [noradrenaline]). Correlation of measurements performed on EDTA plasma, with those performed on heparinized plasma or serum were assessed by intraclass correlation coefficients (ICCs). In test 2, blood samples from five owned cats were collected and stored in EDTA tubes and divided between duplicate Eppendorf tubes labeled as different cats for blinding purposes and analyzed independently for the same four bioamines as in test 1. Reliability of concentration determination for these duplicates was assessed by ICCs and coefficients of variation (CVs). Results: In test 1, there was no significant correlation between the EDTA plasma serotonin and serum serotonin concentrations. There was also no significant correlation between EDTA plasma and heparin plasma concentrations for either epinephrine or norepinephrine. There was a statistically significant but weak correlation between EDTA plasma and heparin plasma dopamine concentrations. In test 2, there was no correlation for repeat-analyzed serotonin and epinephrine concentrations. Although there were statistically significant correlations for dopamine and norepinephrine, CVs for each analyte were in excess of 30%. Conclusions and relevance: Before any further attempt is made to measure and report on neurotransmitter concentrations in domestic cats, it is essential that the robustness of the methodology is carefully validated and the data presented. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Feline Medicine & Surgery is the property of Sage Publications Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Supplemental Index
الوصف
تدمد:1098612X
DOI:10.1177/1098612X20924916