دورية أكاديمية

Experimental Investigations of Reinforced Concrete Columns with Lap-Spliced Crossties Under Cyclic Axial and Lateral Load.

التفاصيل البيبلوغرافية
العنوان: Experimental Investigations of Reinforced Concrete Columns with Lap-Spliced Crossties Under Cyclic Axial and Lateral Load.
المؤلفون: Lee Dr, Associate Researcher, Tai-Kuang, Chen Prof., Cheng-Cheng
المصدر: Structural Engineering International; Feb2024, Vol. 34 Issue 1, p128-140, 13p
مصطلحات موضوعية: LATERAL loads, CONCRETE columns, AXIAL loads, REINFORCED concrete, COMPOSITE columns, COLUMNS, REINFORCING bars
مستخلص: The lap-spliced crosstie is formed by lapping two J-shaped reinforcing bars with a 180° hook at one end and a straight line at the other end, which can address the difficulty and poor construction quality of conventional crossties. This study conducted cyclic lateral load testing of four large reinforced concrete (RC) columns to explore the seismic performance of RC columns with lap-spliced crossties under cyclic axial force. The results are as follows: (1) Under the action of cyclic axial force, all the specimens basically fulfilled the requirements of earthquake-resistant structures under axial compression. The flexural ductility of the specimen with crossties of 180-deg hooks was the best, followed by the specimens using lap-spliced crossties. The specimen with conventional crossties performed the worst. (2) The seismic performance for all the specimens in enduring axial tension was more satisfactory than that for axial compression. (3) When an inner column endures only axial compression during an earthquake with a column axial force ratio of greater than 30%, the use of lap-spliced crossties both meets specification requirements and can facilitate the construction process. (4) When an outer column is subjected to cyclic axial compression and tension during earthquakes, the column axial force ratio is generally less than 30%. Therefore, lap-spliced crossties can be used to replace conventional crossties. (5) For columns that withstand only axial compression, when the column axial force ratio is less than 30%, lap-spliced crossties can be used instead of conventional crossties. (6) RC columns with lap-spliced crossties enclosing lapped longitudinal reinforcements as well as the rectangular column section and intermediate longitudinal reinforcements merit further research and clarification. [ABSTRACT FROM AUTHOR]
Copyright of Structural Engineering International is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Supplemental Index
الوصف
تدمد:10168664
DOI:10.1080/10168664.2022.2161971