Experimental analysis of photovoltaic/thermal system under composite climate in terms of exergy efficiency

التفاصيل البيبلوغرافية
العنوان: Experimental analysis of photovoltaic/thermal system under composite climate in terms of exergy efficiency
المؤلفون: Caliskan, Sinan, Soydan, Ismail Burak, Seyitoglu, Sertac Samed, Guler, Furkan
المصدر: International Journal of Exergy; 2024, Vol. 44 Issue: 1 p65-76, 12p
مستخلص: In this study, we examined data from a photovoltaic thermal (PV/T) module designed with a simple structure in comparison to data from a reference photovoltaic module. The highest thermal efficiency was determined as 74.15%, the highest electrical efficiency was determined as 13.41% for reference PV module and 14.36% for PV/T module at 1.25 l/min flow rate. Thanks to the cooling system, the module surface temperature was reduced and the electrical efficiency was increased by 7.11% at 1.25 l/min flow rate. Furthermore, the maximum exergy efficiency of the PVT panel was calculated to be 16.71%.
قاعدة البيانات: Supplemental Index
الوصف
تدمد:17428297
17428300
DOI:10.1504/IJEX.2024.138740