Investigation of scatter correction, dead time and partial volume effect on lesion and salivary gland dose estimation by radioiodine scintigraphy

التفاصيل البيبلوغرافية
العنوان: Investigation of scatter correction, dead time and partial volume effect on lesion and salivary gland dose estimation by radioiodine scintigraphy
المؤلفون: Abuqbeitah, Mohammad
المساهمون: Demir, Mustafa, İÜC, Lisansüstü Eğitim Enstitüsü, Nükleer Tıp Ana Bilim Dalı, Abuqbeıtah, Mohammad, Nükleer Tıp Anabilim Dalı
بيانات النشر: İstanbul Üniversitesi-Cerrahpaşa, 2020.
سنة النشر: 2020
مصطلحات موضوعية: Radyasyon dozu, Radyoloji ve Nükleer Tıp, Dozimetri, Radiology and Nuclear Medicine, SPECT/BT, İyot tedavisi, Tükürük bezi
الوصف: Amaç: 131I tedavisinden sonra tükürük bezleri ve tiroid bakiye dokusu ve uzak metastazlardaki absorbe radyasyon dozlarını hesaplamaktır. Materyal ve Metod: İçinde çok sayıda kürler olan bir vücut fantomuna 53,6 mCi (1983.2 MBq) 131I konuldu ve 20 SPECT/BT çekimi yapıldı. Hacimleri 26.51,11.49, 5.57, 2.57, 0.52 cm3 olan kürelerin geri kazanım katsayıları hesaplandı. Saçılma düzeltmeleri için saçılma düzeltmesi yapıldı. Daha sonra 31 hastaya ( 73±16 kg, 46±17 yaş) ortalama 137 ± 52 mCi (5069±1924 MBq)131I verildikten sonraki 24 ve 168. saat görüntüleri üzerinden tükürük bezi ve akciğerlerini de içeren taramalar yapıldı. BT görüntüleri esas alınarak %30 izokontur ile tiroid bakiye dokusu ve uzak metastazlar üzerinden ROI'ler çizildi. IDAC-Dose 2.1 programı kullanılarak tükürük bezi, tiroid bakiye dokusu ve lezyonlar birim yoğunluklu küre modeline göre absorbe dozlar hesaplandı. Bulgular: Tek bir parotis (n=31) ve submandibular tükürük bezi için (n=25) ortalama rezidans zamanları 8.6±11.2 ve 3.1±2.2 dakika bulundu. Tiroid bakiye dokusu için ortalama rezidans zamanı 3.52±4.54 saat bulundu. Paratis ortalama absorbe dozu 0.46 ± 0.47 Gy/GBq, submandibular bez absorbe dozu 0.16 ± 0.10 Gy/GBq bulundu. Ortama tükürük dozu (n=25) 0.61 ± 0.48 Gy/GBq ve tiroid bakiye dokusu için (n=22) 78 ± 108 Gy/GBq.- bulundu. Tartışma: Yüksek miktarda 131I aktivitelerinin verilmesinden sonra iki boyutlu sintigrafilerin kullanıldığı görüntüleme tabanlı dozimetriler esas alındığında hesaplanan tükürük bezi dozlarına eşittir.Anahtar kelimeler: İyot tedavisi, Tükürük bezi, SPECT/BT, Radyasyon dozu, Dozimetri Aim: It was aimed to calculate the absorbed dose of salivary gland, thyroid residues and distant metastases after 131I therapy.Material and Methods: Body phantom with multiple spheres was filled by 53.6 mCi (1983.2 MBq) 131I followed by 20 SPECT/CT scans at different time marks. Recovery coefficients were calculated for spheres of 26.51,11.49, 5.57, 2.57, 0.52 cm3 . Triple energy window method was used for scatter correction. Later, 31 patients ( 73±16 kg, 46±17 years) were scanned including salivary glands and lungs at 4, 24, 168 hours following administration of 137 ± 52 mCi (5069±1924 MBq)131I. ROIs were drawn over the salivary glands based on the CT scan while the thyroid residues and the distal lesions were drawn by 30% isocontour. The absorbed doses were calculated using IDAC-Dose 2.1 for salivary glands and unite density sphere model for thyroid residues and lesions.Results: The average residence time of single parotid gland (n = 31) and single submandibular gland (n=25) was 8.6±11.2 and 3.1±2.2 minutes, respectively. While that of thyroid residuas was 3.52±4.54 hours. Mean dose of parotid glands was 0.46 ± 0.47 Gy/GBq and that of the submandibular glands was 0.16 ± 0.10 Gy/GBq. The mean dose of total salivary glands (n = 25) was 0.61 ± 0.48 Gy/GBq and that of thyroid residues (n=22) was 78 ± 108 Gy/GBq.Conclusion: The calculated doses of salivary glands were comparable with other results using planar scintigraphy that verifies the possibility to perform image based dosimetry after administration of large 131I activities.Key Words: Iodine Therapy, Salivary gland, SPECT / CT, Radiation dose, Dosimetry 106
وصف الملف: application/pdf
اللغة: Turkish
URL الوصول: https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::ba29d39d604bf9f922c1dbeed8d1cf70
https://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=4J_FzTwlrMCH4qBROpXPH7-CnGJT0JcyGQjJ5QmRG5wJS9IUMAw2XsaVBHJhOa_E
حقوق: OPEN
رقم الأكسشن: edsair.dedup.wf.001..ba29d39d604bf9f922c1dbeed8d1cf70
قاعدة البيانات: OpenAIRE