In this study, we report 6 plies of 5-harness satin woven fabrics were welded each other by ultra high frequency induction system between two tempered glass surfaces at 400°C under 640 kPa pressure for 120 seconds. The results of mechanical properties, Brinell hardness tests and SEM analysis proved an intimate contact between plies allowing the fusion in the bonding area for PEEK matrix.