A detector setup for the measurement of angular distribution of heavy-ion elastic scattering with low energy on RIBLL

التفاصيل البيبلوغرافية
العنوان: A detector setup for the measurement of angular distribution of heavy-ion elastic scattering with low energy on RIBLL
المؤلفون: Mei-Rong Huang, Gao-Long Zhang, Li-Jie Sun, Lei Zheng, J. B. Ma, Xiao-Tong Chu, H. L. Zang, Xing-Xing Liu, Shi-Wei Xu, Lei Yang, Yang Liu, Ya-Zhou Niu, Zhen-Wei Jiao, Shi-Lun Jin, Yong-Jin Yao, Guang-Xin Zhang, Nan-Rou Ma, Peng Ma, Zhen Bai, Jiecheng Yang, Wei-Wei Qu, Biao Yang, Hui-Ming Jia, Cheng-Jian Lin, Jian-Song Wang
المصدر: Nuclear Science and Techniques. 28
بيانات النشر: Springer Science and Business Media LLC, 2017.
سنة النشر: 2017
مصطلحات موضوعية: Physics, Elastic scattering, Nuclear and High Energy Physics, Ion beam, Physics::Instrumentation and Detectors, 010308 nuclear & particles physics, Scattering, Monte Carlo method, Detector, Coulomb barrier, 01 natural sciences, symbols.namesake, Nuclear Energy and Engineering, 0103 physical sciences, symbols, Rutherford scattering, Atomic physics, 010306 general physics, Beam (structure)
الوصف: A detector setup for the measurement of angular distribution of heavy-ion elastic scattering at energies around Coulomb barrier on the radioactive ion beam line in Lanzhou at the heavy-ion research facility in Lanzhou is designed. The beam profile and the scattering angles on the target are deduced by two parallel plate avalanche counters, and four sets of detector telescopes (including double-sided silicon strip detectors) are placed systematically with the beam line, incorporating with Monte Carlo simulations. The data of $$^{16}\hbox {O}$$ on $$^{89}\hbox {Y}$$ target were analyzed to compare with the simulation results. It is found that the simulated distribution is agreeable with the experimental data. By assuming the pure Rutherford scattering at small scattering angles, the angular distribution of elastic scattering of $${}^{16}\hbox {O} + {}^{89}\hbox {Y}$$ at low energies can be reasonably obtained. It indicates that this set of detector setup can be used for the measurement of angular distributions of heavy-ion elastic scattering at energies around Coulomb barrier.
تدمد: 2210-3147
1001-8042
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::09dd2f1f52bb99c8de8208006749285a
https://doi.org/10.1007/s41365-017-0249-0
حقوق: CLOSED
رقم الأكسشن: edsair.doi...........09dd2f1f52bb99c8de8208006749285a
قاعدة البيانات: OpenAIRE