Predicting in vitro genotoxicity by mouse lymphoma L5178Y thymidine kinase mutation assay (MLA): Accounting for simulated metabolic activation of chemicals

التفاصيل البيبلوغرافية
العنوان: Predicting in vitro genotoxicity by mouse lymphoma L5178Y thymidine kinase mutation assay (MLA): Accounting for simulated metabolic activation of chemicals
المؤلفون: Stefan Kotov, Terry W Schultz, O. Mekenyan, Petko I. Petkov, K. Kirilov, Masamitsu Honma
المصدر: Computational Toxicology. 4:45-53
بيانات النشر: Elsevier BV, 2017.
سنة النشر: 2017
مصطلحات موضوعية: 0301 basic medicine, Genetics, Health, Toxicology and Mutagenesis, In silico, education, Locus (genetics), Plasma protein binding, 010501 environmental sciences, Gene mutation, Biology, Toxicology, 01 natural sciences, In vitro, Computer Science Applications, 03 medical and health sciences, chemistry.chemical_compound, 030104 developmental biology, S9 fraction, Biochemistry, chemistry, Thymidine kinase, DNA, 0105 earth and related environmental sciences
الوصف: The mouse lymphoma L5178Y thymidine kinase locus gene mutation assay (MLA) is typically part of regulatory batteries of methods used for in vitro evaluation of substances eliciting small gene mutations, and gross structural alterations at the chromosomal level. In an effort to make the MLA endpoint amenable to category formation to support assessments of mutagenesis, a model with 52 DNA and 32 protein binding alerts particular to the MLA endpoint has been developed. Each alert is supported by a mechanistic justification, an alert-specific training set and an alert performance evaluation. Subsequently, these alerts have been used in combination with an in vitro rat liver S9 fraction metabolic simulator (the TIssue MEtabolism Simulator (TIMES) platform) to evaluate MLA mutagenicity of likely metabolites of MLA negative parent compounds. The resulting system provides for transparent in silico identification of structural and general parametric requirements, as well as, binding mechanisms in parent chemicals and their simulated metabolites. When applied to the training sets, performance of the TIMES_MLA models, both with and without rat liver S9 activation show high (≥80%) sensitivity, specificity and concordance, which is consistent with the repeatability and reproducibility of experimental MLA results.
تدمد: 2468-1113
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::2e4c63dab8b73f3e7a229c0e7a169507
https://doi.org/10.1016/j.comtox.2017.10.002
حقوق: CLOSED
رقم الأكسشن: edsair.doi...........2e4c63dab8b73f3e7a229c0e7a169507
قاعدة البيانات: OpenAIRE