Recent developments with microchannel-plate PMTs

التفاصيل البيبلوغرافية
العنوان: Recent developments with microchannel-plate PMTs
المؤلفون: A. Hayrapetyan, A. Lehmann, O. Merle, M. Zühlsdorf, F. Uhlig, L. Schmitt, W. Eyrich, A. Belias, Euan N. Cowie, Michaela Thiel, T. Wasem, J. Schwiening, D. Lehmann, A. Gerhardt, F. Nerling, M. Hoek, S. Schlimme, C. Schwarz, M. Cardinali, B. Kröck, M. Krebs, K. Föhl, R. Dzhygadlo, T. Keri, A. Britting, M. Schmidt, Concettina Sfienti, Michael Düren, K. Götzen, M. Traxler, M. Pfaffinger, J. Rieke, M. Patsyuk, M. Böhm, Patrick Achenbach, K. Peters, G. Kalicy, E. Etzelmüller, W. Lauth, G. Schepers
المصدر: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 876:42-47
بيانات النشر: Elsevier BV, 2017.
سنة النشر: 2017
مصطلحات موضوعية: Physics, Nuclear and High Energy Physics, Photon, 010308 nuclear & particles physics, business.industry, Detector, 01 natural sciences, Cathode, 030218 nuclear medicine & medical imaging, Anode, law.invention, 03 medical and health sciences, Wavelength, Atomic layer deposition, 0302 clinical medicine, Optics, law, 0103 physical sciences, Quantum efficiency, Microchannel plate detector, business, Instrumentation
الوصف: Microchannel-plate (MCP) PMTs are the favored photon sensors for the DIRC detectors of the PANDA experiment at FAIR. Until recently the main drawback of MCP-PMTs were serious aging effects which led to a limited lifetime due to a rapidly decreasing quantum efficiency (QE) of the photo cathode (PC) as the integrated anode charge (IAC) increased. In the latest models of PHOTONIS and Hamamatsu an innovative atomic layer deposition (ALD) technique is applied to overcome these limitations. During the last five years comprehensive aging tests with ALD coated MCP-PMTs were performed and the results were compared to tubes treated with other techniques. The QE in dependence of the IAC was measured as a function of the wavelength and the position across the PC. For the best performing tubes the lifetime improvement in comparison to the older MCP-PMTs is a factor of > 50 based on an IAC of meanwhile > 10 C / cm 2 . In addition, the performance results of a new 2-in. ALD coated MCP-PMT prototype from Hamamatsu with a very high position resolution (128×6 anode pixels) is presented and the first conclusions from investigations concerning the PC aging mechanism will be discussed.
تدمد: 0168-9002
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::3b96e74e443774f7acf18de3c48fab39
https://doi.org/10.1016/j.nima.2016.12.063
حقوق: CLOSED
رقم الأكسشن: edsair.doi...........3b96e74e443774f7acf18de3c48fab39
قاعدة البيانات: OpenAIRE