Measuring the current distribution in a 10 m long high temperature superconducting cable conductor

التفاصيل البيبلوغرافية
العنوان: Measuring the current distribution in a 10 m long high temperature superconducting cable conductor
المؤلفون: D. Willen, C.N. Rasmussen, Ole Tønnesen, Chresten Træholt, Finn Thorbjørn Hansen, M. Daumling, S. Krüger Olsen
المصدر: Physica C: Superconductivity. :1567-1570
بيانات النشر: Elsevier BV, 2002.
سنة النشر: 2002
مصطلحات موضوعية: Superconductivity, Materials science, Energy Engineering and Power Technology, Condensed Matter Physics, Electronic, Optical and Magnetic Materials, Conductor, Current sheet, Nuclear magnetic resonance, Skin effect, Electrical and Electronic Engineering, Current (fluid), Composite material, Layer (electronics), Electrical conductor, Rogowski coil
الوصف: To obtain realistic data on high temperature superconducting (HTS) conductors, a 10 m long cable conductor was built using 193 HTS tapes placed in eight concentric layers. To fully exploit the current carrying capability of all the HTS tapes and to minimise the AC losses the conductor was designed to have an almost even current distribution with respect to the HTS tapes. The outer diameter of the former was 35 mm and the outer diameter of the conductor was about 40 mm. A thin layer of electrically insulating Mylar TM foil was wound between each HTS layer. This way, the current in one particular layer may be treated as a tubular current sheet. The current in each layer was determined using custom made flat Rogowski coils placed between the superconducting layers. For this conductor, each layer was carrying
تدمد: 0921-4534
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::3c81d9964b80c2e252205039ec6b93a1
https://doi.org/10.1016/s0921-4534(02)01065-1
حقوق: CLOSED
رقم الأكسشن: edsair.doi...........3c81d9964b80c2e252205039ec6b93a1
قاعدة البيانات: OpenAIRE