Evaluation of a smartphone-based colorimetric method for urinalysis dipstick readings in cats

التفاصيل البيبلوغرافية
العنوان: Evaluation of a smartphone-based colorimetric method for urinalysis dipstick readings in cats
المؤلفون: Vincent Leynaud, Candice Gillet, Rachel Lavoué, Didier Concordet, Brice S Reynolds
المصدر: Journal of Feline Medicine and Surgery. 25:1098612X2311714
بيانات النشر: SAGE Publications, 2023.
سنة النشر: 2023
مصطلحات موضوعية: Small Animals
الوصف: Objectives The aim of the study was to compare the diagnostic performances of a smartphone-based colorimetric method (SBCM) for urinalysis with a semi-automated point-of-care (POC) analyser using standardised solutions and cat urine. Methods Artificial solutions (negative and positive quality controls, and purposely designed artificial urine) and natural urine from 216 cats were used. Two urine reagent strips were simultaneously dipped in each sample. One dipstick was read by the SBCM and the other by the POC analyser at the same time. Results for pH, proteins, bilirubin, ‘blood’, glucose and ketones were considered. Overall agreement and sensitivity, specificity and accuracy of the SBCM were determined based on selected cut-offs. Results For the artificial solutions, 80 comparisons were obtained for each analyte and each expected concentration. The overall agreement (exactly the same result) between the two methods was 78.4%. SBCM sensitivity, specificity and accuracy were 99.0%, 100% and 99.3%, respectively. The correlation between the two methods was almost perfect (Cohen’s kappa coefficient = 0.9851). For natural urine samples, the overall agreement (including pH) was 68.6%. Using optimal cut-offs for the SBCM determined from the results of analysis of artificial solutions, the sensitivity, specificity and accuracy of the SBCM were 100%, 76.02% and 80.5%, respectively. In this situation, the correlation between the two methods was moderate (Cohen’s kappa coefficient = 0.5401). This was mostly due to a high rate of false-positive results for bilirubin (61.1%). Conclusions and relevance With proper cut-off use (ie, considering positive or negative results) the SBCM evaluated here has a perfect sensitivity and appropriate diagnostic performances for proteins, ‘blood’, glucose and ketones. Based on these experimental data, this method appears suitable for dipstick urinalysis but positive results for bilirubin and proteins have to be confirmed.
تدمد: 1532-2750
1098-612X
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::48240c66a35381f6daa2075fe29b9adf
https://doi.org/10.1177/1098612x231171434
حقوق: OPEN
رقم الأكسشن: edsair.doi...........48240c66a35381f6daa2075fe29b9adf
قاعدة البيانات: OpenAIRE