Using a smartwatch to record precordial electrocardiograms: a validation study

التفاصيل البيبلوغرافية
العنوان: Using a smartwatch to record precordial electrocardiograms: a validation study
المؤلفون: J L Van Der Zande, M Strik, R Dubois, S Ploux, S Abu-Alrub, D W Donker, E Oppersma, P Bordachar
المصدر: Europace. 25
بيانات النشر: Oxford University Press (OUP), 2023.
سنة النشر: 2023
مصطلحات موضوعية: Physiology (medical), Cardiology and Cardiovascular Medicine
الوصف: Funding Acknowledgements Type of funding sources: Public grant(s) – National budget only. Main funding source(s): This work received financial support from the French Government as part of the “Investments of the Future” program managed by the National Research Agency (ANR) Background Smartwatches which support recording of a single-lead electrocardiogram (ECG) are increasingly being used worldwide, mainly for detection of atrial fibrillation. Recordings beyond the wrist are anecdotal as their reliability remains unknown. Aim This clinical validation study assessed the reliability of an Apple Watch (AW) to obtain frontal and precordial leads as compared with standard 12-lead ECGs in both healthy subjects and patients with underlying heart disease. Methods In 100 subjects (80 with ECG anomalies), a standard 12-lead ECG was performed, followed by AW recordings of the standard Einthoven leads (leads I, II, and III) and precordial leads V1, V3, and V6. Seven parameters (P, QRS, ST and T-wave amplitudes, PR, QRS, and QT intervals) were compared through a Bland-Altman analysis including bias (mean difference), absolute offset (mean absolute difference), and 95% limits of agreement. Results No significant differences were observed for any parameter across any lead, except for R-wave measured across precordial leads V1, V3, and V6 where significantly greater amplitudes were measured by the AW, (0.20 mV; 0.19mV; 0.49 mV respectively; p = 9x10-7; p = 7x10-4; p = 6x10-14, respectively), indicating overestimation by the AW. There were no significant differences in absolute offset or bias for any parameters of any leads (p > 0.05). Conclusion ECGs recorded with the AW on the wrist but also on other positions had comparable durations and amplitudes compared to standard 12-lead ECG. The AW can be used to record frontal and precordial leads, paving the way for broader clinical applications.
تدمد: 1532-2092
1099-5129
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::53c76732679df2cd30745c5b570adc5a
https://doi.org/10.1093/europace/euad122.637
حقوق: OPEN
رقم الأكسشن: edsair.doi...........53c76732679df2cd30745c5b570adc5a
قاعدة البيانات: OpenAIRE