Load optimization of central cooling system pumps of a container ship for the slow steaming conditions to enhance the energy efficiency

التفاصيل البيبلوغرافية
العنوان: Load optimization of central cooling system pumps of a container ship for the slow steaming conditions to enhance the energy efficiency
المؤلفون: Cengiz Deniz, Caglar Dere
المصدر: Journal of Cleaner Production. 222:206-217
بيانات النشر: Elsevier BV, 2019.
سنة النشر: 2019
مصطلحات موضوعية: Slow steaming, Renewable Energy, Sustainability and the Environment, 020209 energy, Strategy and Management, 05 social sciences, 02 engineering and technology, Diesel engine, Industrial and Manufacturing Engineering, Automotive engineering, Waste heat recovery unit, Diesel fuel, Engine room, 050501 criminology, 0202 electrical engineering, electronic engineering, information engineering, Fuel efficiency, Water cooling, Environmental science, Electric power, 0505 law, General Environmental Science
الوصف: The implementation of International Maritime Organization regulations for CO2 emission reduction has oriented ships to sail at lower speeds. Speed reduction reduces fuel consumption of ships significantly. In order to perform efficient ship operation, energy demand throughout the whole engine room has to be decreased. The goal of the study is to minimize electrical power consumption during slow steaming operation, hence equivalent fuel consumption and emissions could be decreased. A computational study was carried out in order to clarify potential savings with respect to main engine load. The study quantifies the energy savings in main engine cooling system which has significant potential to reduce electrical power consumption in slow steaming operations. Operational requirements are determined with the help of realistic engine room simulator of a container ship which has waste heat recovery system. The values, obtained from the simulator were verified using the technical manual of a diesel engine, which have similar output power range. The results of calculations show that there is great potential to improve energy efficiency when variable pumps are used. Based on the results, from the main engine cooling system, 60% of electrical power demand reduction can be achieved. The power reduction saved by pumps, decreases considerable amount of marine diesel oil consumption as 296.2 tons where 367.4 tons of fuel needed by diesel generators or oil fired boiler. The reduction in fuel consumption is 80% that the saving in the central cooling system corresponds 948 tons of CO2 emission reduction and $207,300 cost saving.
تدمد: 0959-6526
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::8bd3178ddccfd7715f72ef350b8d77a1
https://doi.org/10.1016/j.jclepro.2019.03.030
حقوق: CLOSED
رقم الأكسشن: edsair.doi...........8bd3178ddccfd7715f72ef350b8d77a1
قاعدة البيانات: OpenAIRE