TAGUCHI METHOD-BASED OPTIMIZATION OF THE MINIMUM DETECTABLE DIFFERENCE OF A CARDIAC X-RAY IMAGING SYSTEM USING A PRECISE LINE PAIR GAUGE

التفاصيل البيبلوغرافية
العنوان: TAGUCHI METHOD-BASED OPTIMIZATION OF THE MINIMUM DETECTABLE DIFFERENCE OF A CARDIAC X-RAY IMAGING SYSTEM USING A PRECISE LINE PAIR GAUGE
المؤلفون: Samrit Kittipayak, Lung-Kwang Pan, Ke-Lin Chen, Lung-Fa Pan, Keng-Yi Wu
المصدر: Journal of Mechanics in Medicine and Biology. 19:1940030
بيانات النشر: World Scientific Pub Co Pte Lt, 2019.
سنة النشر: 2019
مصطلحات موضوعية: Physics, business.industry, Biomedical Engineering, X-ray, 030204 cardiovascular system & hematology, Gauge (firearms), 030218 nuclear medicine & medical imaging, 03 medical and health sciences, Taguchi methods, 0302 clinical medicine, Optics, Line pair, business, Image resolution
الوصف: Objective: To optimize the minimum detectable difference (MDD) of a cardiac X-ray imaging system using the Taguchi L8(27) analysis and a precise line pair (LP) gauge. Methods: The optimal combination of the four critical factors of the cardiac X-ray imaging system, namely X-ray focus, kilovoltage (kVp), milliamper-seconds (mAs) and source image distance (SID), providing the MDD was calculated via the Taguchi analysis and experimentally verified. Two (low and high) levels were assigned for each factor, and eight combinations of four factors were used to acquire instant X-ray images using an NDT commercial LP gauge (with a gauge length of 64[Formula: see text]mm and a width of [Formula: see text][Formula: see text]mm). The latter had five lines and was split gradually from top to bottom for the inspection of X-ray images, whose quality was ranked by three well-trained radiologists according to the double-blind criterion. The ranking grade was given by sharp contrast, low noise and precision to distinguish the LP. Accordingly, the MDD was derived to represent the spatial resolution of instant X-ray images by the revised Student’s [Formula: see text]-test analysis. The optimal combination of factors was experimentally identified and clinically verified in the follow-up inspections. Results: For the conventional setting, Group No. 7 (which obtained the highest grade among eight groups) and the optimal setting, the obtained MDD values were [Formula: see text], [Formula: see text] and [Formula: see text][Formula: see text]mm, respectively, while the LP (line pair/mm) interpolated from the gauge scale amounted to [Formula: see text], [Formula: see text] and [Formula: see text][Formula: see text]LP/mm, respectively. Conclusion: The Taguchi L8 analysis was proved to be instrumental in optimizing the cardiac X-ray imaging system MDD and is recommended to be used jointly with the revised Student’s [Formula: see text]-test analysis for improving the spatial resolution of instant X-ray images.
تدمد: 1793-6810
0219-5194
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::9165bcccbb0536c8875d181c0f7cee47
https://doi.org/10.1142/s021951941940030x
رقم الأكسشن: edsair.doi...........9165bcccbb0536c8875d181c0f7cee47
قاعدة البيانات: OpenAIRE