Xylenol Orange-Functionalized Halloysite Nanotubes as a Novel Adsorbent for Selective Solid-phase Extraction and Determination of Trace Noble Elements

التفاصيل البيبلوغرافية
العنوان: Xylenol Orange-Functionalized Halloysite Nanotubes as a Novel Adsorbent for Selective Solid-phase Extraction and Determination of Trace Noble Elements
المؤلفون: Zheng Hong, Bo Li, Dongfang Huang, Zeyu Liu, Shuya Wang, Amin Bao
المصدر: Journal of the Chinese Chemical Society. 64:953-961
بيانات النشر: Wiley, 2017.
سنة النشر: 2017
مصطلحات موضوعية: Detection limit, Xylenol orange, Elution, Analytical chemistry, 02 engineering and technology, General Chemistry, 010501 environmental sciences, 021001 nanoscience & nanotechnology, 01 natural sciences, chemistry.chemical_compound, Adsorption, Certified reference materials, chemistry, Xylenol, Solid phase extraction, 0210 nano-technology, Enrichment factor, 0105 earth and related environmental sciences, Nuclear chemistry
الوصف: A novel method using xylenol orange-modified halloysite nanotubes as a solid-phase sorbent has been developed for the simultaneous preconcentration and separation of trace Au(III) and Pd(II) prior to their determination by inductively coupled plasma-atomic emission spectrometry (ICP-AES). The experimental effects of pH, the amount of adsorbent, sample flow rate, sample volume, interfering ions, and the elution condition were investigated in detail. Au(III) and Pd(II) were retained on the column at pH 3, and eluted with 2.0 mL of 1.0 mol/L HCl + 2% CS(NH2)2 solution. Common interfering ions did not have any impact on the adsorption, separation, and determination. An enrichment factor of 150 was obtained. The maximum adsorption capacities of the adsorbent were 41.63 and 47.82 mg/g for Au(III) and Pd(II), respectively, under the optimum conditions. By the definition of IUPAC, the detection limits (3σ) of this method for Au(III) and Pd(II) were 0.31 and 0.27 ng/mL, and the relative standard deviations (RSDs) were 2.7 and 3.2%, respectively (n = 8). This newly developed method was verified by certified reference materials, and has been successfully applied to the determination of trace Au(III) and Pd(II) in mine samples with satisfactory results. It can be confidently predicted that the method can be used for the determination trace Au(III) and Pd(II) in other real samples because of its high selectivity, sensitivity, and reproducibility.
تدمد: 0009-4536
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::916d922d9b2fc3956998c1cba6233f19
https://doi.org/10.1002/jccs.201700111
حقوق: CLOSED
رقم الأكسشن: edsair.doi...........916d922d9b2fc3956998c1cba6233f19
قاعدة البيانات: OpenAIRE