Mechanical System Surveillance Test Interval Optimization

التفاصيل البيبلوغرافية
العنوان: Mechanical System Surveillance Test Interval Optimization
المؤلفون: J. D. Lewins, Yun-Fu Wu
المصدر: Journal of Nuclear Science and Technology. 30:1225-1233
بيانات النشر: Informa UK Limited, 1993.
سنة النشر: 1993
مصطلحات موضوعية: Nuclear and High Energy Physics, Computer simulation, Computer science, Monte Carlo method, Failure rate, Interval (mathematics), Reliability engineering, Test (assessment), law.invention, Mechanical system, Nuclear Energy and Engineering, law, Nuclear power plant, Unavailability
الوصف: In general, functional tests are required periodically to detect failures in standby equipment as a means of assuring their availability on demand. However, these functional tests may have an adverse impact on the system availability, because of their potential negative effects such as unavailability at the period of testing, increase of failure rate resulting from excessive wear due to testing. Therefore, in principle, there is an optimal test interval for each standby system. As it normally is difficult to determine analytically the optimal test interval for the real systems in the industry, we therefore introduce the Monte Carlo simulation method for this purpose. In this paper, a one-component system was chosen firstly to introduce the concept of test interval optimization as well as the feasibility of using Monte Carlo simulation. Secondly, a real system in the nuclear power plant. Standby-liquid-control system, was studied using Monte Carlo simulation technique. The promising results obtain...
تدمد: 1881-1248
0022-3131
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::9268abbcdd50d758d1c690e2ce694017
https://doi.org/10.1080/18811248.1993.9734616
رقم الأكسشن: edsair.doi...........9268abbcdd50d758d1c690e2ce694017
قاعدة البيانات: OpenAIRE