The experimental study of the hybrid fixation in ACL reconstruction

التفاصيل البيبلوغرافية
العنوان: The experimental study of the hybrid fixation in ACL reconstruction
المؤلفون: Mihai Roman, Géza Husi, Nicolae Florin Cofaru, Ileana Ioana Cofaru
المصدر: International Review of Applied Sciences and Engineering. 3:113-117
بيانات النشر: Akademiai Kiado Zrt., 2012.
سنة النشر: 2012
مصطلحات موضوعية: Orthodontics, Environmental Engineering, Computer science, Materials Science (miscellaneous), Anterior cruciate ligament, General Engineering, Management Science and Operations Research, musculoskeletal system, surgical procedures, operative, medicine.anatomical_structure, medicine, Hamstring Tendons, Graft fixation, Information Systems, Fixation (histology)
الوصف: The article is approaching an interesting topic regarding ACL reconstruction using the hamstring tendons (semitendinosus and gracilis) as the graft. The initial graft fixation after ACL reconstruction is mechanical and it must assure the stability of the system until the biologic integration takes place. No fixation system is as strong as the native ACL insertion. Therefore, hibrid fixation like an improvement of simple fixation is a field worth studying. The fixation shown in this article is the Hybrid fixation consisting of direct fixation with interference screw and an extra cortical fixation over a cortical screw.
تدمد: 2062-0810
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::9268f15fa4cd829c71bae78df1d397fe
https://doi.org/10.1556/irase.3.2012.2.4
حقوق: OPEN