Trends in adoption of extravascular devices compared to conventional devices: real-world data from the Netherlands Heart Registration

التفاصيل البيبلوغرافية
العنوان: Trends in adoption of extravascular devices compared to conventional devices: real-world data from the Netherlands Heart Registration
المؤلفون: K T N Breeman, M D Van Der Stoel, V F Van Dijk, S C Yap, L Van Erven, A H Maass, L V A Boersma, A A M Wilde, R E Knops, F V Y Tjong
المصدر: Europace. 25
بيانات النشر: Oxford University Press (OUP), 2023.
سنة النشر: 2023
مصطلحات موضوعية: Physiology (medical), Cardiology and Cardiovascular Medicine
الوصف: Funding Acknowledgements Type of funding sources: None. Introduction Extravascular devices (EVD), such as the subcutaneous ICD (S-ICD) and leadless pacemaker (LP), have been developed to circumvent pocket- and lead-related device complications. Knowledge on trends in adoption of these devices among patient categories and hospital types is mainly derived from industry-initiated studies or selected populations. Purpose To assess the real-world nationwide trends in adoption of EVDs in the Netherlands. Methods Using real-world data registered at the Netherlands Heart Registration from 72 Dutch device-implanting hospitals, all consecutive patients were included with an EVD implantation (de novo or replacement) from 2012-2020. To describe the relative adoption of EVDs, all consecutive patients with a single-chamber conventional ICD or pacemaker were also included (pacemakers from 2014, the first LP registration). Trends in EVD adoption are described for different patient (age, gender, and BMI) and hospital (tertiles of device-implanting volume and implanting center [general , intervention, or thorax]) characteristics. Differences in adoption were tested using Chi-square and Fisher’s exact tests. Results From 2012-2020, 2862 S-ICDs and 15806 single-chamber conventional ICDs were implanted, while from 2014-2020, 785 LPs and 16530 single-chamber conventional pacemakers were implanted. S-ICD use among single-chamber ICD recipients increased from 7% to 22% and LP use among single-chamber pacemaker recipients increased from 1% to 8%, although utilization has levelled off in recent years (Fig. 1). The relative use of S-ICDs was largest in patients aged 10-30 years and declined with higher age (p Conclusions Although EVDs have been adopted early in the Netherlands, their utilization has levelled off in recent years, possibly driven by higher cost, battery issues, or the COVID-19 pandemic. Utilization of S-ICDs is highest among younger patients while utilization of LPs was not specifically high in certain age groups. The effects of gender and BMI were smaller. EVDs were mainly implanted in high-volume thorax centers.
تدمد: 1532-2092
1099-5129
2012-2020
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::9b656c9eac3fa99797f0b85d471e512c
https://doi.org/10.1093/europace/euad122.429
حقوق: OPEN
رقم الأكسشن: edsair.doi...........9b656c9eac3fa99797f0b85d471e512c
قاعدة البيانات: OpenAIRE
الوصف
تدمد:15322092
10995129
20122020