Over-catheter tract suture to prevent bleeding and air embolism after tunnelled catheter removal
العنوان: | Over-catheter tract suture to prevent bleeding and air embolism after tunnelled catheter removal |
---|---|
المؤلفون: | Tomasz Gołębiowski, Waldemar Letachowicz, Krzysztof Letachowicz, Mariusz Kusztal, Wacław Weyde, Marian Klinger, Jan Penar |
المصدر: | The Journal of Vascular Access. 18:170-172 |
بيانات النشر: | SAGE Publications, 2016. |
سنة النشر: | 2016 |
مصطلحات موضوعية: | medicine.medical_specialty, business.industry, medicine.medical_treatment, 030232 urology & nephrology, Dialysis catheter, 030204 cardiovascular system & hematology, medicine.disease, Air embolism, Surgery, 03 medical and health sciences, Catheter, 0302 clinical medicine, Suture (anatomy), Blood loss, Embolism, Nephrology, medicine, Catheter removal, business, Central venous catheter |
الوصف: | Introduction Severe, life-threating, complications might occur on dialysis catheter removal. Methods We present a useful technique that may prevent vascular air embolism and severe bleeding. Results The suture is placed around the catheter and tied over previous tract just after device removal. Conclusions Applying a compressing suture to the tract left after removal of a tunnelled haemodialysis catheter is a simple manoeuvre that could prevent severe complication. |
تدمد: | 1724-6032 1129-7298 |
URL الوصول: | https://explore.openaire.eu/search/publication?articleId=doi_________::a4eaeb6ee1df764384aec38f3657fa2d https://doi.org/10.5301/jva.5000620 |
حقوق: | CLOSED |
رقم الأكسشن: | edsair.doi...........a4eaeb6ee1df764384aec38f3657fa2d |
قاعدة البيانات: | OpenAIRE |
تدمد: | 17246032 11297298 |
---|