Seismic Capacity Evaluation of Full-size Two-story R/C Frame Strengthened with HSWF External Connection Method by Pseudo-dynamic Test

التفاصيل البيبلوغرافية
العنوان: Seismic Capacity Evaluation of Full-size Two-story R/C Frame Strengthened with HSWF External Connection Method by Pseudo-dynamic Test
المؤلفون: Yun-Chul Choi, Dae-Sung Hwang, Bok-Gi Lee, Kang-Seok Lee, You-Sok Kimi
المصدر: Journal of the Korea Concrete Institute. 31:89-97
بيانات النشر: Korea Concrete Institute, 2019.
سنة النشر: 2019
مصطلحات موضوعية: Mechanics of Materials, business.industry, Materials Science (miscellaneous), Frame (networking), External connection, Building and Construction, Structural engineering, business, Civil and Structural Engineering, Mathematics, Dynamic testing
الوصف: 본 연구에서는 기존 강도증진형 내진보강법의 단점을 보완 · 개선할 수 있는 새로운 개념의 내진보강법인 HSWF(H-section Steel Window-typed Frame) 외부접합형 내진보강공법을 제안하였다. HSWF 내진보강법은 거주자가 거주가 가능하면서 내진보강 공사를 실시할 수가 있으며, 접합부 시공성이 탁월하며, 특히 필요 내진보강량 산정이 간편한 전형적인 강도증진형으로 전단파괴가 지배적인 비내진상세를 가지는 국내 철근콘크리트 건물에는 내력확보가 용이한 내진보강공법이다. 본 연구에서 제안한 HSWF 외부접합형 공법의 유용성을 검증 할 목적으로 기존 비내진상세를 가지는 철근콘크리트 학교건물을 바탕으로 한 실물 2층 골조 실험체를 대상으로 유사동적실험을 실시하여 검증함과 동시에 내진보강효과를 검토하였다. 그 결과, 국내 내진설계용 지진수준인 200 gal 지진규모에서 무보강 골조는 붕괴를 하였지만, HSWF 외부접합형 내진보강법으로 보강한 골조는 경미한 지진피해가 예상되었으며, 국내에서 발생 가능한 최대 지진규모(300 gal)를 상정한 경우에도 소규모 이하의 지진피해가 예상되어 본 연구에서 개발한 HSWF 내진보강법의 유효성이 검증되었다고 사료된다.
تدمد: 2234-2842
1229-5515
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::ae860a2730649c7a8db35a74367aae5b
https://doi.org/10.4334/jkci.2019.31.1.089
رقم الأكسشن: edsair.doi...........ae860a2730649c7a8db35a74367aae5b
قاعدة البيانات: OpenAIRE