Cyclic Potentiodynamic Polarization on Titanium Alloys Anodizing in Alkaline Solutions

التفاصيل البيبلوغرافية
العنوان: Cyclic Potentiodynamic Polarization on Titanium Alloys Anodizing in Alkaline Solutions
المؤلفون: Joel Salgado, Citlalli Gaona Tiburcio, Jesús Manuel Jáquez-Muñoz, C. Martínez-Ramos, Patricia del Carmen Zambrano Robledo, Maria del Refugio Lara Banda, F. Estupiñán-Lopez, Facundo Almeraya Calderón, José Ángel Cabral Miramontes
المصدر: ECS Transactions. 110:49-61
بيانات النشر: The Electrochemical Society, 2023.
سنة النشر: 2023
مصطلحات موضوعية: General Medicine
الوصف: Titanium alloys are used in different industries such as biomedical, aerospace, aeronautic, chemical, and naval. Those industries have high requirements with few damage tolerances. The aim of this work was to study the corrosion behavior of titanium alloys anodizing and non-anodizing in alkaline (KOH and NaOH) solutions, exposed in 3.5%wt. NaCl and 3.5% wt. H2SO4 solutions at room temperature using cyclic potentiodynamic polarization (CPP) according to standards to obtain electrochemical parameters as the passivation range (PR), corrosion type, passive layer persistence, corrosion potential (Ecorr), and corrosion rate. The alloy Ti Beta-C anodized presented better corrosion resistance than Ti-6Al-4V in both media. The smallest corrosion rate is presented in Beta-C samples (4.72 E-8 A/cm2) and the highest corrosion rate is CP2 (1.61 E-5 A/cm2)
تدمد: 1938-6737
1938-5862
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::efea215b43184c5a33eb9b3791909d7b
https://doi.org/10.1149/11001.0049ecst
حقوق: CLOSED
رقم الأكسشن: edsair.doi...........efea215b43184c5a33eb9b3791909d7b
قاعدة البيانات: OpenAIRE