Crucial Aspects for Using Computational Fluid Dynamics as a Predictive Evaluation Tool for Blood Pumps

التفاصيل البيبلوغرافية
العنوان: Crucial Aspects for Using Computational Fluid Dynamics as a Predictive Evaluation Tool for Blood Pumps
المؤلفون: Simon J. Sonntag, Ulrich Steinseifer, Sascha Gross-Hardt, Tim A.S. Kaufmann, Fiete Boehning, Thomas Schmitz-Rode
المصدر: ASAIO Journal. 65:864-873
بيانات النشر: Ovid Technologies (Wolters Kluwer Health), 2019.
سنة النشر: 2019
مصطلحات موضوعية: Computer science, Biomedical Engineering, Biophysics, Bioengineering, 030204 cardiovascular system & hematology, Computational fluid dynamics, Biomaterials, 03 medical and health sciences, 0302 clinical medicine, Shear stress, Humans, Computer Simulation, Hydraulic pump, business.industry, Models, Cardiovascular, Turbulence modeling, Reproducibility of Results, General Medicine, Mechanics, Characteristic velocity, Blood pump, Shear (sheet metal), Pressure head, 030228 respiratory system, Hydrodynamics, Heart-Assist Devices, Stress, Mechanical, business
الوصف: The suitability of computational fluid dynamics (CFD) as a regulatory tool for safety assessment of medical devices is still limited: A lack of standardized validation and evaluation methods impairs the quantitative comparability and reliability of simulation studies, particularly regarding the assessment of hemocompatibility. This study investigated important aspects of validation and verification for three common turbulence modeling approaches (laminar, k-ω shear stress transport [SST] and stress-blended eddy simulation [SBES]) and three different mesh refinements. Simulation results for pressure head, characteristic velocity, and shear stress for the benchmark blood pump model of the Food and Drug Administration critical path initiative were compared with its published experimental results. For the highest mesh resolution, all three models predicted the hydraulic pump characteristics with a relative deviation averaged over six operating conditions below 6.1%. In addition, the SBES model showed an accurate agreement of the characteristic velocity field in the pump's diffusor region (relative error2.9%), while the laminar and SST model calculated significantly elevated and deviating velocity amplitudes (43.6%). The ability to quantify shear stress is fundamental for the prediction of blood damage. In this respect, this study demonstrated that: 1) a close agreement and validation of both pressure head and characteristic velocity was feasible and 2) the shear stress quantification demanded higher near-wall mesh resolutions, although such high resolutions were not required for the validation of only pressure heads or velocity. Hence, a mesh verification analysis for shear stresses may prove significant for the development of credible CFD blood damage predictions in the future.
تدمد: 1058-2916
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::04f59fc643456402f7dfffe13181657a
https://doi.org/10.1097/mat.0000000000001023
رقم الأكسشن: edsair.doi.dedup.....04f59fc643456402f7dfffe13181657a
قاعدة البيانات: OpenAIRE