Evaluating the Impact of Applying Personal Glucose Targets in a Closed-Loop System for People With Type 1 Diabetes

التفاصيل البيبلوغرافية
العنوان: Evaluating the Impact of Applying Personal Glucose Targets in a Closed-Loop System for People With Type 1 Diabetes
المؤلفون: Mustafa Fattah, Charlotte K. Boughton, Julia Ware, Janet M. Allen, Sara Hartnell, Malgorzata E. Willinska, Ajay Thankamony, Carine de Beaufort, Fiona M. Campbell, Elke Fröhlich-Reiterer, Sabine E. Hofer, Thomas M. Kapellen, Birgit Rami-Merhar, Atrayee Ghatak, Tabitha L. Randell, Rachel E. J. Besser, Daniela Elleri, Nicola Trevelyan, Louise Denvir MD, Nikki Davis, Lia Bally, Hood Thabit, Lalantha Leelarathna, Mark L. Evans, Julia K. Mader, Roman Hovorka
المساهمون: Boughton, Charlotte K [0000-0003-3272-9544], Ware, Julia [0000-0002-4497-0979], Besser, Rachel EJ [0000-0002-4645-6324], Thabit, Hood [0000-0001-6076-6997], Leelarathna, Lalantha [0000-0001-9602-1962], Evans, Mark L [0000-0001-8122-8987], Mader, Julia K [0000-0001-7854-4233], Hovorka, Roman [0000-0003-2901-461X], Apollo - University of Cambridge Repository
المصدر: Fattah, Mustafa; Boughton, Charlotte K; Ware, Julia; Allen, Janet M; Hartnell, Sara; Willinska, Malgorzata E; Thankamony, Ajay; de Beaufort, Carine; Campbell, Fiona M; Fröhlich-Reiterer, Elke; Hofer, Sabine E; Kapellen, Thomas M; Rami-Merhar, Birgit; Ghatak, Atrayee; Randell, Tabitha L; Besser, Rachel E J; Elleri, Daniela; Trevelyan, Nicola; Denvir Md, Louise; Davis, Nikki; ... (2022). Evaluating the Impact of Applying Personal Glucose Targets in a Closed-Loop System for People With Type 1 Diabetes. (In Press). Journal of diabetes science and technology(19322968221145184), p. 19322968221145184. Diabetes Technology Society 10.1177/19322968221145184 <http://dx.doi.org/10.1177/19322968221145184>
بيانات النشر: Diabetes Technology Society, 2022.
سنة النشر: 2022
مصطلحات موضوعية: glucose control, algorithm, type 1 diabetes, Endocrinology, Diabetes and Metabolism, Biomedical Engineering, Internal Medicine, 610 Medicine & health, Bioengineering, hybrid closed-loop, personal glucose target, 610 Medizin und Gesundheit
الوصف: Background CamAPS FX is a hybrid closed-loop smartphone app used to manage type one diabetes. The closed-loop algorithm has a default target glucose of 5.8 mmol/L (104.5 mg/dL), but users can select personal glucose targets (adjustable between 4.4 mmol/L and 11.0 mmol/L [79 mg/dL and 198 mg/dL, respectively]). Method In this post-hoc analysis, we evaluated the impact of personal glucose targets on glycemic control using data from participants in five randomized controlled trials. Results Personal glucose targets were widely used, with 20.3% of all days in the data set having a target outside the default target bin (5.5-6.0 mmol/L [99-108 mg/dL]). Personal glucose targets >6.5 mmol/L (117 mg/dL) were associated with significantly less time in target range (3.9-10.0 mmol/L [70-180 mg/dL]; 6.5-7.0 mmol/L [117-126 mg/dL]: mean difference = −3.2 percentage points [95% CI: −5.3 to −1.2; P < .001]; 7.0-7.5 mmol/L [126-135 mg/dL]: −10.8 percentage points [95% CI: −14.1 to −7.6; P < .001]). Personal targets >6.5 mmol/L (117 mg/dL) were associated with significantly lower time (Conclusions Discrete study populations showed differences in glucose control when applying similar personal targets.
وصف الملف: application/pdf
DOI: 10.48350/176337
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::08fb55c4a5d398e856afba8dd456eed3
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....08fb55c4a5d398e856afba8dd456eed3
قاعدة البيانات: OpenAIRE