Estereoeletroencefalografia na era da cirurgia guiada por imagem
العنوان: | Estereoeletroencefalografia na era da cirurgia guiada por imagem |
---|---|
المؤلفون: | Fernando Antonio Patriani Ferraz, Ricardo Silva Centeno, Luís Otávio Sales Ferreira Caboclo, Henrique Carrete Junior, Ana Paula Hamad, Elza Márcia Targas Yacubian, Sergio Cavalheiro |
المساهمون: | Universidade Federal de São Paulo (UNIFESP) |
المصدر: | Repositório Institucional da UNIFESP Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP Journal of Epilepsy and Clinical Neurophysiology, Volume: 15, Issue: 4, Pages: 178-183, Published: DEC 2009 Journal of Epilepsy and Clinical Neurophysiology v.15 n.4 2009 Journal of epilepsy and clinical neurophysiology Liga Brasileira de Epilepsia (LBE) instacron:LBE |
بيانات النشر: | Liga Brasileira de Epilepsia (LBE), 2009. |
سنة النشر: | 2009 |
مصطلحات موضوعية: | stereoelectroencephalography, Epilepsy, Neurology, Physiology (medical), eletrodo profundo, cirurgia guiada por imagem, Neurology (clinical), imaging guide surgery, depth electrode, Epilepsia, estereoeletroencefalografia |
الوصف: | INTRODUÇÃO: A estereoeletroencefalografia (E-EEG), conforme introduzida na década de 50 por Talairach, é um método invasivo de análise tridimensional da zona epilpeptogênica, baseado na técnica de implantação intracraniana de eletrodos de profundidade (EP). O advento das modernas técnicas de cirurgia guiadas por imagem revolucionaram a técnica de implantação dos EP. OBJETIVO: O objetivo deste artigo é discutir os princípios da E-EEG e sua evolução, desde a era Talairach até a era atual, da cirurgia guiada por imagem, e suas perspectivas futuras. CONCLUSÕES: Embora os princípios gerais da E-EEG tenham permanecidos intactos ao longo dos anos, a implantação de EP, que é a técnica cirúrgica que viabiliza este método, sofreu uma tremenda evolução ao longo das últimas três décadas devido ao advento das modernas técnicas de imagem, de sistemas de computação e das novas técnicas estereotáxicas. O uso de sistemas robotizados, a evolução constante das técnicas de imagem e computação e a utilização de EP com sondas para micro diálise associados a si, abre no futuro uma enorme perspectiva para a aplicação dos EP e da E-EEG, tanto para uso investigativo como terapêutico. A descoberta de novos alvos, em localizações profundas e a fabricação de eletrodos inteligentes, poderá incrementar, num futuro próximo, a necessidade do uso deste método. INTRODUCTION: The stereoelectroencephalography (SEEG), introduced by Talairach in 50', is an invasive method of tridimensional analysis of epileptogenic zone based on the intracranial placement of depth electrodes (DE). The advent of modern imaging guided surgery had a tremendous impact in DE implantation techniques. OBJETIVE: The aim of this article is to discuss the main principles of SEEG and its evolution along the years since Talairach era until the imaging guide surgery era, with its new perspectives. CONCLUSIONS: Although the main principles of SEEG have remained intact, the placement of depth electrodes (DE) which is the surgical technique that supports this method has suffered a tremendous evolution along the last three decades due the advent of the modern imaging, the computer systems and the new stereotactic techniques. The use of robotic, the new imaging and computed systems and the use of probes of micro dialise adaptated to EP opened a tremendous perspective to DE and SEEG application as an investigative and therapeutical method. The discovery of new targets in deep brain localization and the manufacturing of smart DE, can increment, in a near future, the number of indications to this method. Universidade Federal de São Paulo (UNIFESP) Departamento de Neurologia e Neurocirurgia Universidade Federal de São Paulo (UNIFESP) Departamento de Diagnóstico por Imagem UNIFESP, Depto. de Neurologia e Neurocirurgia UNIFESP, Depto. de Diagnóstico por Imagem SciELO |
وصف الملف: | text/html |
اللغة: | Portuguese |
URL الوصول: | https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0b284d032c18f3466142daafcb49a50d http://repositorio.unifesp.br/handle/11600/5355 |
حقوق: | OPEN |
رقم الأكسشن: | edsair.doi.dedup.....0b284d032c18f3466142daafcb49a50d |
قاعدة البيانات: | OpenAIRE |
الوصف غير متاح. |