Development of a high performance liquid chromatography-tandem mass method for determination of bis(7)-tacrine, a promising anti-Alzheimer's dimer, in rat blood

التفاصيل البيبلوغرافية
العنوان: Development of a high performance liquid chromatography-tandem mass method for determination of bis(7)-tacrine, a promising anti-Alzheimer's dimer, in rat blood
المؤلفون: Yifan Han, Ge Lin, Li Zhang, Yuan Ping Pang, Jason M.K. Ho, Bobby W.H. Cheng, Hua Yu, Kelvin K.W. Kan, Kelvin Chan, Zhe Ming Gu, Yitao Wang, Wenming Li
المصدر: Journal of Pharmaceutical and Biomedical Analysis. 44:1133-1138
بيانات النشر: Elsevier BV, 2007.
سنة النشر: 2007
مصطلحات موضوعية: Male, Time Factors, Metabolic Clearance Rate, Formic acid, Electrospray ionization, Clinical Biochemistry, Ethyl acetate, Pharmaceutical Science, Mass spectrometry, Tandem mass spectrometry, Sensitivity and Specificity, High-performance liquid chromatography, Analytical Chemistry, Rats, Sprague-Dawley, chemistry.chemical_compound, Drug Stability, Alzheimer Disease, Tandem Mass Spectrometry, Freezing, Drug Discovery, Animals, Chromatography, High Pressure Liquid, Spectroscopy, Chromatography, Molecular Structure, Elution, Reproducibility of Results, Rats, chemistry, Area Under Curve, Injections, Intravenous, Tacrine, Quantitative analysis (chemistry), Half-Life
الوصف: An analytical method using on-line high performance liquid chromatography-tandem mass spectrometry with electrospray ionization was developed and applied for the quantification of bis(7)-tacrine (B7T) in rat blood. B7T and pimozide (internal standard, IS) were extracted in a single step from 100 microl of alkalized blood with ethyl acetate. Analytes were separated using an Extend C-18 column at 25 degrees C. The elution was achieved isocratically with a mobile phase composed of 0.05% aqueous formic acid and acetonitrile (60:40, v/v) at a flow rate of 0.35 ml/min. Quantification was achieved by monitoring the selected ions at m/z 247 for B7T and m/z 462-->m/z 328 for pimozide. Retention times were 1.45 and 2.23 min for B7T and IS, respectively. Calibration curves were linear in the range from 86.4 to 2160.0 ng/ml. The established method is rapid, selective and sensitive for the identification and quantification of B7T in biological samples. The assay is accurate (bias
تدمد: 0731-7085
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0cdfece9d689d4ef812d9eeb2854fcb5
https://doi.org/10.1016/j.jpba.2007.05.028
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....0cdfece9d689d4ef812d9eeb2854fcb5