Progress in the development of the neutron flux monitoring system of the French GEN-IV SFR: simulations and experimental validations

التفاصيل البيبلوغرافية
العنوان: Progress in the development of the neutron flux monitoring system of the French GEN-IV SFR: simulations and experimental validations
المؤلفون: H. Hamrita, S. Jacobsson Svärd, G. de Izarra, Carl Hellesen, A-C. Scholer, Philippe Molinié, N. Chapoutier, F. Jadot, M. Bakkali, B. Cantonnet, R. Hanna, Vasudha Verma, Philippe Dessante, Emmanuel Odic, D. Verrier, Michael J. Kirkpatrick, J-C. Nappe, Zs. Elter, C. Jammes, P. Filliatre
المساهمون: Département Etude des Réacteurs (DER), CEA-Direction des Energies (ex-Direction de l'Energie Nucléaire) (CEA-DES (ex-DEN)), Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA), Chalmers University of Technology, Department of Applied Physics, Division of Nuclear Engineering, SE-412 96 Göteborg, Sweden, Uppsala University, Laboratoire Capteurs et Architectures Electroniques (LCAE), Département Métrologie Instrumentation & Information (DM2I), Laboratoire d'Intégration des Systèmes et des Technologies (LIST (CEA)), Direction de Recherche Technologique (CEA) (DRT (CEA)), Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Direction de Recherche Technologique (CEA) (DRT (CEA)), Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay-Laboratoire d'Intégration des Systèmes et des Technologies (LIST (CEA)), Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay, AREVA NP, AREVA NP - Centre Technique (FRANCE), PHOTONIS France S.A.S, Nuclear Instrumentation, Laboratoire Génie électrique et électronique de Paris (GeePs), Université Paris-Sud - Paris 11 (UP11)-Université Pierre et Marie Curie - Paris 6 (UPMC)-CentraleSupélec-Centre National de la Recherche Scientifique (CNRS), The study was performed in the framework of an on-going collaboration on the instrumentation and safety of sodium cooled fast reactors between Chalmers, Uppsala University and CEA with support from the Swedish Research Council. The authors are also grateful to AREVA for their contribution to this work and support within the TECNA project., Division of Applied Nuclear Physics, Uppsala University, Box 516, SE-75120 Uppsala, Sweden, Laboratoire d'Intégration des Systèmes et des Technologies (LIST), Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay-Laboratoire d'Intégration des Systèmes et des Technologies (LIST)
المصدر: 4th International Conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA)
4th International Conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), Apr 2015, Lisbon, Portugal. ⟨10.1109/ANIMMA.2015.7465647⟩
بيانات النشر: HAL CCSD, 2015.
سنة النشر: 2015
مصطلحات موضوعية: Experimental validation, Materials science, Monitoring, Fission, Nuclear engineering, Astrophysics::High Energy Astrophysical Phenomena, French GEN-IV SFR, GEN-IV sodium-cooled fast reactor, Nuclear instrumentation, [PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex], Inductor, 01 natural sciences, 010305 fluids & plasmas, Physics::Geophysics, Neutron flux, 0103 physical sciences, Inductors, Neutron, Temperature sensors, [PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det], Nuclear Experiment, Reactor pressure vessel, Fission reactor instrumentation, Neutrons, 010308 nuclear & particles physics, Liquid metal fast breeder reactors, Detector, Monitoring system, Reactor operating, Detectors, Reactor vessel, Neutron flux monitoring system, Cascading style sheets, Safety
الوصف: International audience; The neutron flux monitoring system of the French GEN-IV sodium-cooled fast reactor will rely on high-temperature fission chambers installed in the reactor vessel and capable of operating over a wide-range neutron flux. The definition of such a system is presented and the technological solutions are justified with the use of simulation and experimental results.
اللغة: English
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0e60d09697582cb37e3cb3ec9b788476
https://centralesupelec.hal.science/hal-01282997/file/article_ChristianJammes.pdf
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....0e60d09697582cb37e3cb3ec9b788476