Dynamic CTA in Native Kidneys Using a Multiphase CT Protocol-Potential of Significant Reduction of Contrast Medium

التفاصيل البيبلوغرافية
العنوان: Dynamic CTA in Native Kidneys Using a Multiphase CT Protocol-Potential of Significant Reduction of Contrast Medium
المؤلفون: Frederik F. Strobl, Margarita Braunagel, Manfred Stangl, Maximilian F. Reiser, Dirk A. Clevert, Andreas Helck, Florian Ortner, Antje Habicht, Andreas Schindler, Ulf Schönermarck, Christoph Trumm
المصدر: Academic radiology. 25(7)
سنة النشر: 2017
مصطلحات موضوعية: Adult, Male, Computed Tomography Angiography, media_common.quotation_subject, Contrast-induced nephropathy, Contrast Media, Perfusion scanning, Signal-To-Noise Ratio, Kidney, Radiation Dosage, Renal Veins, 030218 nuclear medicine & medical imaging, 03 medical and health sciences, Young Adult, 0302 clinical medicine, Renal Artery, medicine.artery, Image noise, Medicine, Contrast (vision), Humans, Radiology, Nuclear Medicine and imaging, Aorta, Computed tomography angiography, media_common, Aged, Retrospective Studies, medicine.diagnostic_test, business.industry, Middle Aged, medicine.disease, Contrast medium, 030220 oncology & carcinogenesis, Mann–Whitney U test, Female, business, Nuclear medicine, Artifacts
الوصف: RATIONALE AND OBJECTIVE The objective of this study was to assess an optimized renal multiphase computed tomography angiography (MP-CTA) protocol regarding reduction of contrast volume. MATERIALS AND METHODS Thirty patients underwent MP-CTA (12 phases, every 3.5 seconds, 80 kV/120 mAs) using 30 mL of contrast medium. The quality of MP-CTA was assessed quantitatively measuring vessel attenuation, image noise, and contrast-to-noise ratio. MP-CTA was evaluated qualitatively regarding depiction of vessels, cortex differentiation, and motion artifacts (grades 1-4, 1 = best). Mean effective radiation dose was registered. Results were compared to standard renal computed tomography angiography (CTA) (80 mL). Student t test was applied, if variables followed normal distribution. For other variables, nonparametric Mann-Whitney U test was used. RESULTS All acquisitions were successfully performed, and no patient had to be excluded from the study. MP-CTA enabled high attenuation (aorta: 503 ± 91 HU, renal arteries: 450 ± 73 HU/456 ± 72 HU) at adequate image noise (13.7 ± 1.5) and good contrast-to-noise ratio (34.2 ± 10.2). Good attenuation of renal veins was observed (286 ± 43 HU/282 ± 42 HU). Arterial enhancement was significantly higher compared to renal CTA (aorta: 396 ± 90 HU, renal arteries: 331 ± 74 HU/333 ± 80 HU; P
تدمد: 1878-4046
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::1186281466b0ff1958ade02f3ab60270
https://pubmed.ncbi.nlm.nih.gov/29545025
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....1186281466b0ff1958ade02f3ab60270