Prospective long-term results and quality-of-life assessment after Dura-II penile prosthesis placement

التفاصيل البيبلوغرافية
العنوان: Prospective long-term results and quality-of-life assessment after Dura-II penile prosthesis placement
المؤلفون: Kenneth H. Ferguson, R. Duane Cespedes
المصدر: Urology. 61:437-441
بيانات النشر: Elsevier BV, 2003.
سنة النشر: 2003
مصطلحات موضوعية: Adult, Male, medicine.medical_specialty, Sexual Behavior, Urology, medicine.medical_treatment, Penile Implantation, Prosthesis, Patient satisfaction, Erectile Dysfunction, medicine, Humans, Longitudinal Studies, Prospective Studies, Mechanical reliability, Aged, Aged, 80 and over, business.industry, Penile prosthesis, Equipment Design, Long term results, Middle Aged, medicine.disease, Surgery, Treatment Outcome, medicine.anatomical_structure, Erectile dysfunction, Patient Satisfaction, Quality of Life, Penile Prosthesis, Sexual function, business, Penis
الوصف: Objectives To evaluate prospectively the long-term device reliability and patient satisfaction after Dura-II malleable penile prosthesis implantation. Methods Between 1992 and 1996, 94 patients underwent Dura-II implantation for erectile dysfunction. Patients were prospectively examined and completed standardized questionnaires regarding sexual activity, prosthesis function, intercourse satisfaction, and overall quality of life. An independent statistician analyzed these data. Results The mean patient age was 63 years, and the mean patient follow-up was 5.7 years. Eighty-five patients were available for long-term evaluation. Fourteen patients died during the follow-up period. One patient was lost to follow-up, and eight prostheses (9%) were explanted; however, no mechanical defects were found in the explanted prostheses. Seventy-six percent and 87% of patients reported satisfactory rigidity and ease of concealing the device, respectively. Seventy-six percent of patients remained sexually active during the evaluation period, and 87% of patients reported that the prosthesis improved their overall quality of life. Eighty-five percent would undergo the implant surgery again, and 88% percent of patients would recommend the Dura-II prosthesis to a friend. Conclusions The Dura-II malleable penile prosthesis provides good rigidity, ability to conceal the device, and mechanical reliability, as demonstrated by the results of this long-term study. Most patients stated they would have the prosthesis placed again and would recommend it to a friend.
تدمد: 0090-4295
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::12decb99630932d99db5ed9420dde02f
https://doi.org/10.1016/s0090-4295(02)02270-7
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....12decb99630932d99db5ed9420dde02f
قاعدة البيانات: OpenAIRE