Evaluation of six different airway devices regarding regurgitation and pulmonary aspiration during cardio-pulmonary resuscitation (CPR) – A human cadaver pilot study

التفاصيل البيبلوغرافية
العنوان: Evaluation of six different airway devices regarding regurgitation and pulmonary aspiration during cardio-pulmonary resuscitation (CPR) – A human cadaver pilot study
المؤلفون: Bernard Roessler, Kurt Ruetzler, Georg Goliasch, Tobias Piegeler, Henrik Fischer, Susanna Lang, Martin Schlaepfer
المصدر: Resuscitation. 102:70-74
بيانات النشر: Elsevier BV, 2016.
سنة النشر: 2016
مصطلحات موضوعية: Adult, Male, Laryngeal tube, medicine.medical_specialty, medicine.medical_treatment, Pilot Projects, Emergency Nursing, Aspiration pneumonia, Manikins, Pneumonia, Aspiration, Laryngeal Masks, 03 medical and health sciences, 0302 clinical medicine, Bronchoscopy, Cadaver, Intubation, Intratracheal, Laryngopharyngeal Reflux, medicine, Humans, Intubation, 030212 general & internal medicine, Cardiopulmonary resuscitation, Airway Management, Aged, Aged, 80 and over, medicine.diagnostic_test, business.industry, 030208 emergency & critical care medicine, Equipment Design, Middle Aged, medicine.disease, Respiration, Artificial, Cardiopulmonary Resuscitation, Heart Arrest, Surgery, Pulmonary aspiration, Anesthesia, Emergency Medicine, Female, Airway management, Cardiology and Cardiovascular Medicine, business
الوصف: Background Chest compressions and ventilation are lifesaving tasks during cardio-pulmonary resuscitation (CPR). Besides oxygenation, endotracheal intubation (ETI) during CPR is performed to avoid aspiration of gastric contents. If intubation is difficult or impossible, supraglottic airway devices are utilized. We tested six different airway devices regarding their potential to protect against regurgitation and aspiration during CPR in a randomized experimental human cadaver study. Methods Five-hundred ml of 0.01% methylene-blue-solution were instilled into the stomach of 30 adult human cadavers via an oro-gastric tube. The cadavers were then randomly assigned to one of six groups, resulting in 5 cadavers in each group. Airway management was performed with either bag-valve ventilation, Laryngeal Tube, EasyTube, Laryngeal Mask (Classic), I-Gel, or ETI. Thereafter 5 min of CPR were performed according to the 2010 Guidelines of the European Resuscitation Council. Pulmonary aspiration was defined as the presence of methylene-blue-solution below the vocal cords or the ETI cuff as assessed by fiber-optic bronchoscopy. Results Thirty cadavers were included (14 females, 16 males). Aspiration was detected in three out of five cadavers receiving bag-valve ventilation and in two out of five intubated with LMA or I-Gel. In cadavers intubated with the LT, aspiration occurred in one out of five cases. No aspiration could be detected in cadavers intubated with ETI and EasyTube. Conclusion This study provides experimental evidence that, during CPR, ETI offers superior protection against regurgitation and pulmonary aspiration of gastric contents than supraglottic airway devices or bag-valve ventilation.
تدمد: 0300-9572
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::171b925985dae61a401eca84bd5e685c
https://doi.org/10.1016/j.resuscitation.2016.02.017
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....171b925985dae61a401eca84bd5e685c
قاعدة البيانات: OpenAIRE