A new automated turbidimetric immunoassay for the measurement of canine C-reactive protein

التفاصيل البيبلوغرافية
العنوان: A new automated turbidimetric immunoassay for the measurement of canine C-reactive protein
المؤلفون: Anna Bassols, Lourdes Soler, Yolanda Saco, Natalia Juan García, Francesca Canalias, Raquel Pato, Fermín Lampreave, Carlos Torrente, Matilde Piñeiro, Raquel Peña
المصدر: Veterinary Clinical Pathology. 47:130-137
بيانات النشر: Wiley, 2018.
سنة النشر: 2018
مصطلحات موضوعية: Detection limit, Chromatography, General Veterinary, biology, medicine.diagnostic_test, 040301 veterinary sciences, Chemistry, Immunoturbidimetry, C-reactive protein, 04 agricultural and veterinary sciences, 0403 veterinary science, Automation, 03 medical and health sciences, C-Reactive Protein, Dogs, 0302 clinical medicine, Method comparison, Fully automated, Reference Values, 030220 oncology & carcinogenesis, Immunoassay, biology.protein, medicine, Animals
الوصف: In dogs, as in humans, C-reactive protein (CRP) is a major acute phase protein that is rapidly and prominently increased after exposure to inflammatory stimuli. CRP measurements are used in the diagnosis and monitoring of infectious and inflammatory diseases.The study aim was to develop and validate a turbidimetric immunoassay for the quantification of canine CRP (cCRP), using canine-specific reagents and standards.A particle-enhanced turbidimetric immunoassay was developed. The assay was set up in a fully automated analyzer, and studies of imprecision, limits of linearity, limits of detection, prozone effects, and interferences were carried out. The new method was compared with 2 other commercially available automated immunoassays for cCRP: one turbidimetric immunoassay (Gentian CRP) and one point-of-care assay based on magnetic permeability (Life Assays CRP).The within-run and between-day imprecision were1.7% and 4.2%, respectively. The assay quantified CRP proportionally in an analytic range up to 150 mg/L, with a prozone effect appearing at cCRP concentrations320 mg/L. No interference from hemoglobin (20 g/L), triglycerides (10 g/L), or bilirubin (150 mg/L) was detected. Good agreement was observed between the results obtained with the new method and the Gentian cCRP turbidimetric immunoassay.The new turbidimetric immunoassay (Turbovet canine CRP, Acuvet Biotech) is a rapid, robust, precise, and accurate method for the quantification of cCRP. The method can be easily set up in automated analyzers, providing a suitable tool for routine clinical use.
تدمد: 0275-6382
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::1eafefe536f51a3ac0e5f310d34f0ae6
https://doi.org/10.1111/vcp.12576
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....1eafefe536f51a3ac0e5f310d34f0ae6
قاعدة البيانات: OpenAIRE