The bicipital tuberosity and distal radius are unreliable landmarks for radial head implant alignment

التفاصيل البيبلوغرافية
العنوان: The bicipital tuberosity and distal radius are unreliable landmarks for radial head implant alignment
المؤلفون: James A. Johnson, George S. Athwal, Ryan N. Katchky, Graham J.W. King
المصدر: Journal of Shoulder and Elbow Surgery. 22:1242-1247
بيانات النشر: Elsevier BV, 2013.
سنة النشر: 2013
مصطلحات موضوعية: Adult, Elbow, Elbow Prosthesis, Tendons, Imaging, Three-Dimensional, Orientation (geometry), Elbow Joint, Cadaver, medicine, Humans, Body Weights and Measures, Orthopedics and Sports Medicine, Rotational alignment, Aged, Aged, 80 and over, business.industry, Arthroplasty, Replacement, Elbow, Reproducibility of Results, Radial head, General Medicine, Radius, Anatomy, Middle Aged, medicine.anatomical_structure, Surgery, Radial head fracture, Implant, Tomography, Anatomic Landmarks, business
الوصف: Background As more anatomic asymmetric radial head implants emerge, it is necessary to determine the optimal landmarks to ensure correct rotational orientation. The bicipital tuberosity and distal radius are possible bony landmarks that can be used for rotational alignment of asymmetric prostheses; however, they have not been validated. The purpose of this study was to evaluate the reliability of the bicipital tuberosity and distal radius as rotational landmarks for orientation of asymmetric radial head prostheses. Methods Measurements were made from computer tomography scans of 50 elbows in order to determine the rotational relationships between the radial head, bicipital tuberosity, biceps tendon footprint, and distal radius. Results The maximum radial head diameter was oriented 65° ± 28° from the bicipital tuberosity, 119° ± 38° from the biceps tendon footprint, 82° ± 29° from the radial styloid, and 76° ± 28° from the volar surface of the distal radius. All of these landmarks had a significantly greater variance than a proposed acceptable clinical tolerance of 10° ( P Conclusion The results demonstrate that the measured landmarks show no consistent rotational relationship with the maximum diameter of the radial head. In order to maximize the utility of more anatomic asymmetric radial head implant systems, further studies are necessary to identify more reliable rotational landmarks to ensure optimal implant positioning.
تدمد: 1058-2746
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::1ec2669d028e5b47ae22359233c12e1e
https://doi.org/10.1016/j.jse.2013.02.013
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....1ec2669d028e5b47ae22359233c12e1e
قاعدة البيانات: OpenAIRE