Reconstruction left atrium and isolation pulmonary veins of paroxysmal atrial fibrillation using single contact force catheter with zero x-ray exposure: A CONSORT Study

التفاصيل البيبلوغرافية
العنوان: Reconstruction left atrium and isolation pulmonary veins of paroxysmal atrial fibrillation using single contact force catheter with zero x-ray exposure: A CONSORT Study
المؤلفون: Jian Qiang Zhang, Jian-Zeng Dong, Jia Bing Liang, Rong Hui Yu, D Y Long, Chang Sheng Ma, C H Sang
المصدر: Medicine
سنة النشر: 2017
مصطلحات موضوعية: Male, Time Factors, medicine.medical_treatment, 030204 cardiovascular system & hematology, Electrocardiography, 0302 clinical medicine, Atrial Fibrillation, 030212 general & internal medicine, medicine.diagnostic_test, Atrial fibrillation, General Medicine, Equipment Design, Clinical Trial/Experimental Study, zero x-ray exposure, Middle Aged, Radiation Exposure, Ablation, Catheter, Surgery, Computer-Assisted, Pulmonary Veins, Cardiology, Catheter Ablation, Female, Patient Safety, Research Article, medicine.medical_specialty, Catheters, Catheter ablation, 03 medical and health sciences, Imaging, Three-Dimensional, Internal medicine, Occupational Exposure, Image Interpretation, Computer-Assisted, medicine, Humans, Heart Atria, Aged, Risk Management, business.industry, Odds ratio, medicine.disease, Confidence interval, single catheter, reconstruction left atrium, Fluoroscopy, Angiography, atrial fibrillation ablation, business
الوصف: Background: Conventional ablation of paroxysmal atrial fibrillation (PAF) is associated with radiation risks for patients and laboratory staff. Three-dimensional (3D) mapping system capable of showing contact force (CF) and direction of catheter tip may compensate for nonfluoroscopic safety issues. Objective: The aim of this study was to investigate the feasibility of zero x-ray exposure during reconstruction left atrium (LA) and ablation. Methods: Single, CF catheter, and 3D mapping system were used to reconstruct LA and isolate pulmonary veins (PV) in all patients. The patients were randomly divided into 2 groups after LA angiography. In group 1, reconstruction LA and isolation PV was performed with the help of 3D system (without x-ray), whereas in group 2, x-ray and 3D system were utilized to reconstruct LA and ablate PV antrum. After ablation, Lasso catheter was used to confirm the PV isolation. All patients were followed up to 12 months. Results: A total of 342 PAF patients were continuously enrolled. The basic clinical characteristics between the 2 groups had no significant difference. Parameters related to the procedure, average procedure time, ablation procedure time, average contact force (CF) applied, the percentage of time within CF settings, and average power applied during radiofrequency application showed no significant difference between the 2 groups. In group 1, the average fluoroscopy time before LA reconstruction was similar to that in group 2 (2.8 ± 0.4 vs. 2.4 ± 0.6 minutes, P = .75). The average fluoroscopy time during ablation was significantly lower than that in group 2 (0 vs. 7.6 ± 1.3 minutes, P
تدمد: 1536-5964
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::217b9a0761a045b3bed9a409f10cbe97
https://pubmed.ncbi.nlm.nih.gov/29019873
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....217b9a0761a045b3bed9a409f10cbe97
قاعدة البيانات: OpenAIRE