A novel rabbit thromboembolic occlusion model

التفاصيل البيبلوغرافية
العنوان: A novel rabbit thromboembolic occlusion model
المؤلفون: David F. Kallmes, Yang Liu, Yong Hong Ding, Karen M. Doyle, Daniel R. Jakaitis, Daying Dai, Luis E. Savastano, Waleed Brinjikji, Ramanathan Kadirvel, Seán Fitzgerald
المصدر: J Neurointerv Surg
سنة النشر: 2020
مصطلحات موضوعية: medicine.medical_specialty, Middle Cerebral Artery, Arterial Occlusive Diseases, Right Common Iliac Artery, Article, medicine.artery, Internal medicine, Occlusion, medicine, Animals, Common carotid artery, Thrombectomy, Aorta, business.industry, Infarction, Middle Cerebral Artery, General Medicine, Aortic bifurcation, Arterial occlusion, Stroke, medicine.anatomical_structure, Treatment Outcome, Middle cerebral artery, Cardiology, Surgery, Stents, Neurology (clinical), Rabbits, Internal carotid artery, business
الوصف: BackgroundTo develop a preclinical thromboembolic occlusion model for studying revascularization strategies.MethodsClot analog with barium sulfate was injected into the distal aorta in 9 New Zealand white rabbits. The situation of aorta occlusion was compared among fibrin-rich (n=4), red blood cell (RBC)-rich (n=3), and whole blood clot analogs (n=2) using digital subtraction angiography. Arterial geometries, histologic features and circumferential stretch of the distal aorta in rabbits were compared with the common carotid artery in swine and the distal internal carotid artery (ICA) in humans. Aspiration thrombectomy and mechanical thrombectomy using a stent retriever were performed in two rabbits.ResultsThe aortic bifurcation was occluded after a single delivery of clot in 4 cases. It was occluded after the second clot injection in the 5 remaining rabbits. Fragmentation of RBC-rich clots occurred during clot injection in 2 cases. The mean diameters of the distal aorta and right common iliac artery in rabbits were 3.7±0.4 and 2.8±0.3 mm, respectively; the mean diameters of human ICA, and first and second segments of the middle cerebral artery (M1, M2) were 3.6±0.4, 3.1±0.4, and 2.4±0.4 mm, respectively. Arterial revascularization was achieved in both rabbits. Geometric, mechanical and histological factors of the distal aorta in rabbit were more close to human distal ICA than swine carotid artery.ConclusionArterial occlusion can be achieved at the aortic bifurcation in rabbits, which is comparable to human ICA bifurcation. This thrombectomy model has the potential to be used for testing of thrombectomy devices.
تدمد: 1759-8486
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::23581c863858db3ff51c5922bbb25cb9
https://pubmed.ncbi.nlm.nih.gov/33574137
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....23581c863858db3ff51c5922bbb25cb9
قاعدة البيانات: OpenAIRE