Effective length measurements of prototype Main Injector Dipole endpacks

التفاصيل البيبلوغرافية
العنوان: Effective length measurements of prototype Main Injector Dipole endpacks
المؤلفون: D.J. Harding, B.C. Brown, H.D. Glass
بيانات النشر: Office of Scientific and Technical Information (OSTI), 1993.
سنة النشر: 1993
مصطلحات موضوعية: Nuclear physics, Physics, Dipole, Series (mathematics), Field (physics), law, Magnet, Particle accelerator, Fermilab, Main injector, Magnetic dipole, law.invention, Computational physics
الوصف: An endpack design has been developed for the Fermilab Main Injector Dipole. A major part of the design process was the testing of a series of prototype removable endpacks. The magnetic parameters that were tested included the effective length and the field shape variation. This report presents a description of the measurement techniques and the results for the effective length. The final endpack has an effective length at 1500 A (0.29T) of 2.6 {plus_minus} 0.3 mm greater than the steel length, and the change in effective length from 1500 A to maximum current of 9500 A (1.74T) is {minus}1.88 {plus_minus} 0.05 mm.
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::242bfad3ef1a09d9b3ecb33bdad9adc1