Comparison of human T cell leukemia virus-1/2 (HTLV-1/2) screening assays in South America: Implications in the loss of blood units

التفاصيل البيبلوغرافية
العنوان: Comparison of human T cell leukemia virus-1/2 (HTLV-1/2) screening assays in South America: Implications in the loss of blood units
المؤلفون: Carolina Andrea Berini, Camila Cánepa, Jorgelina L. Blejer, Mirna M. Biglione, Adriana Alter, Sergio Bontti, Elida Iriarte, Eulalia Rodriguez, Roberto Fernández, Gabriela Pataccini, Williams René Pedrozo, Cecilia María Delfino, Jimena Salido, Richard Malan, Cristina Salomón, Gustavo Duarte, Vanessa Schneider, Marcelo A. Borda
المصدر: Retrovirology
بيانات النشر: Springer Nature
مصطلحات موضوعية: medicine.medical_specialty, Screening test, Specific test, biology, business.industry, medicine.disease, Human T cell leukemia virus, Leukemia, Infectious Diseases, Internal medicine, Virology, Immunology, False positive paradox, biology.protein, Oral Presentation, Medicine, Blood units, Antibody, business, Variable number
الوصف: Although the detection of HTLV antibodies became mandatory in Argentinean blood banks since 2005, there is no recommendation on how to perform the screening. As a consequence, there is a variable number of HTLV false positives depending on the kit used. The aim of the present study was to evaluate the performance of six commercial screening tests available currently for the initial diagnosis of HTLV-1/2 infection in South America. The positive panel included 14 HTLV-1 and 13 HTLV-2 samples confirmed by WB (HTLV-1/2 MP Diagnostics). The negative panel included 233 samples analysed with Architect (n=47), Diapro (n=46), MP (n=45), Murex (n=47) and Serodia (n=48), collected in 5 different institutions in a period of one up to 10 consecutive days. All of them were confirmed by n-PCR. The sensitivity for all HTLV diagnostic kits was 100.0%. The most specific test was Serodia (PA) (99,1%; 2/233), followed by the ELISAs: Celquest (98.3%, 4/233), Murex (97.8%; 5/233), MP and Architect (97.4%; 6/233), and Diapro (93,1%; 16/233). According to this data, 2 to 16 blood units out of 233 should have been discarded due to false positive results in a period of 10 days. This data must be considered when choosing the assays, not only to obtain an optimal efficiency on HTLV-1/2 diagnosis, to increase the number of potential blood units and to decrease the circulation of anxious individuals without a final result, but also to lower the overall cost-benefits of the diagnosis in the health care system.
اللغة: English
تدمد: 1742-4690
DOI: 10.1186/1742-4690-11-s1-o16
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::35103fdfaa872b7cf94653d7f8f98b01
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....35103fdfaa872b7cf94653d7f8f98b01
قاعدة البيانات: OpenAIRE
الوصف
تدمد:17424690
DOI:10.1186/1742-4690-11-s1-o16