Does the size of the needle influence the number of portal tracts obtained through percutaneous liver biopsy?

التفاصيل البيبلوغرافية
العنوان: Does the size of the needle influence the number of portal tracts obtained through percutaneous liver biopsy?
المؤلفون: Diana Gherhardt, Diana Herman, Maria Cornianu, Ioan Sporea, Roxana Sirli, Simona Bota, Alina Popescu
المصدر: Annals of Hepatology, Vol 11, Iss 5, Pp 691-695 (2012)
بيانات النشر: Elsevier, 2012.
سنة النشر: 2012
مصطلحات موضوعية: Adult, Liver Cirrhosis, Male, medicine.medical_specialty, Percutaneous, Biopsy, Menghini needle, Specialties of internal medicine, Severity of Illness Index, Hepatitis B, Chronic, Predictive Value of Tests, Internal medicine, medicine, Humans, Retrospective Studies, Chi-Square Distribution, Hepatology, medicine.diagnostic_test, Romania, business.industry, Liver Diseases, Equipment Design, General Medicine, Portal tracts, Hepatitis C, Chronic, Middle Aged, Liver biopsy, Prognosis, Needle size, Liver, RC581-951, Needles, Predictive value of tests, Percutaneous liver biopsy, Female, Radiology, business
الوصف: Aim. Liver biopsy (LB) is often essential for the diagnosis and staging of chronic viral hepatitis. The aim of our paper was to establish if the size of the biopsy needle influences the number of portal tracts obtained through LB. Material and methods. We conducted a retrospective study on 596 echoassisted percutaneous LBs performed in the Department of Gastroenterology and Hepatology Timisoara during a 4 years period. We included only those biopsy results that had mentioned both the type of needle and the number of portal tracts. All LBs were echoassisted and performed with Menghini modified needles 1.4 and 1.6 mm in diameter (technique with two passages into the liver). The liver fragments were analyzed by a senior pathologist and Knodell score was used to describe necroinflammatory activity as well as fibrosis. We compared the number of portal tracts obtained with 1.4 vs. 1.6 Menghini needles. Results. Type 1.4 mm Menghini needles were used for 80 LBs, while 1.6 mm type were used in 516 LBs. Liver fragments obtained with 1.6 mm Menghini needles had a significantly higher mean number of portal tracts as compared to those obtained with 1.4 needles (24.5 ± 10.6 vs. 20.8 ± 8.6, p = 0.003). Conclusion. The 1.6 mm Menghini needles provide better liver biopsy specimens, with higher number of portal tracts, as compared to 1.4 mm Menghini needles.
اللغة: English
تدمد: 1665-2681
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::365fde515b7742ef01f7e5a7fe606750
http://www.sciencedirect.com/science/article/pii/S1665268119314449
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....365fde515b7742ef01f7e5a7fe606750
قاعدة البيانات: OpenAIRE