مصطلحات موضوعية: Adult, Reoperation, Pulmonary and Respiratory Medicine, Peak pressure, Cardiac-Gated Imaging Techniques, Heart Valve Diseases, Computed tomography, Bioprosthetic valve, Aortic valve replacement, Multidetector Computed Tomography, Female patient, Multidetector computed tomography, medicine, Humans, cardiovascular diseases, Device Removal, Bioprosthesis, Heart Valve Prosthesis Implantation, medicine.diagnostic_test, business.industry, Gastroenterology, Reduced mobility, General Medicine, medicine.disease, Echocardiography, Orifice area, Heart Valve Prosthesis, cardiovascular system, Female, Surgery, Cardiology and Cardiovascular Medicine, business, Nuclear medicine
الوصف: A 32-year-old female patient presented with shortness of breath. The patient had received aortic valve replacement with a 25-mm bioprosthetic valve at the age of 22, and had had two babies, postoperatively. Ten years later, echocardiography showed the calcifi ed bioprosthetic valve with a high peak pressure gradient (70 mmHg) and a reduced valve orifice area (0.46 cm(2)). Electrocardiographically gated multidetector row computed tomography (ECG-gated MDCT) clearly demonstrated calcifi ed bioprosthetic cusps with reduced mobility, and the valve orifi ce area was measured to be 0.64 cm(2) by direct planimetry. These fi ndings observed by ECG-gated MDCT were confi rmed at reoperation. This is the fi rst reported reoperation case of aortic structural valve deterioration clearly visualized by ECG-gated MDCT.
تدمد: 2186-1005
1341-1098
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::49ce5b0df50f36b176cfd93c3a860124
https://doi.org/10.5761/atcs.cr.12.01988
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....49ce5b0df50f36b176cfd93c3a860124
قاعدة البيانات: OpenAIRE