Predictors of Left Ventricular Outflow Tract Obstruction After Transcatheter Mitral Valve Replacement in Severe Mitral Annular Calcification: An Analysis of the Transcatheter Mitral Valve Replacement in Mitral Annular Calcification Global Registry

التفاصيل البيبلوغرافية
العنوان: Predictors of Left Ventricular Outflow Tract Obstruction After Transcatheter Mitral Valve Replacement in Severe Mitral Annular Calcification: An Analysis of the Transcatheter Mitral Valve Replacement in Mitral Annular Calcification Global Registry
المؤلفون: Tarun Chakravarty, Ashish Pershad, Marina Urena, Charanjit S. Rihal, Muhammad Rizwan Sardar, Asim N. Cheema, David Holzhey, Mackram F. Eleid, William W. O'Neill, Georges Kaddissi, Sami Alnasser, Alec Vahanian, Vijay Iyer, Mohammed Nejjari, Mohammed Al-Hijji, Danny Dvir, Raj Makkar, Abdallah El Sabbagh, John G. Webb, Dominique Himbert, Firas Zahr, Dee Dee Wang, Mayra Guerrero, H. Kenith Fang
المصدر: Circulation: Cardiovascular Interventions. 14
بيانات النشر: Ovid Technologies (Wolters Kluwer Health), 2021.
سنة النشر: 2021
مصطلحات موضوعية: Heart Valve Prosthesis Implantation, Cardiac Catheterization, medicine.medical_specialty, Mitral annular calcification, business.industry, medicine.medical_treatment, Mitral valve replacement, Ventricular outflow tract obstruction, Ventricular Outflow Obstruction, Catheter, Treatment Outcome, medicine.anatomical_structure, Heart Valve Prosthesis, Internal medicine, Mitral valve, medicine, Cardiology, Humans, Mitral Valve, Registries, Heart valve, medicine.symptom, Cardiology and Cardiovascular Medicine, business
الوصف: Background: Several studies have evaluated preprocedural imaging predictors of left ventricular outflow tract obstruction (LVOTO) after transcatheter mitral valve replacement. The patient cohorts in these studies were heterogeneous and included patients with transcatheter mitral valve replacement in failed bioprostheses, annuloplasty rings, and severe mitral annular calcification (MAC). The goal of this study was to evaluate predictors of LVOTO specific to patients undergoing valve-in-MAC. Methods: This study included patients with severe MAC who underwent valve-in-MAC and had optimal quality preprocedural multidetector row computed tomography scans eligible for retrospective analysis. Baseline demographic, echocardiographic, and procedural data on these patients were collected. multidetector row computed tomography parameters were analyzed for association with LVOTO, defined as increase in mean LVOT gradient by ≥10 mm Hg with accompanying hemodynamic instability. Results: Seventy-one patients with optimal preprocedural computed tomography scans were included in this study (mean age, 72.5±13.5 years), 9 of which developed LVOTO (all female). Baseline mean LVOT area, neo-LVOT area (145.3 versus 270.9 mm 2 ; P =0.006), indexed neo-LVOT area (90.1 versus 157.4; P =0.05), and virtual transcatheter heart valve to septum distance (3.1 versus 6.9 mm; P =0.002) were lower in the LVOTO group. Expected % LVOT area reduction was higher in the latter group (58.3 versus 42.7%; P =0.008). In the univariable analysis, the baseline mean LVOT area, neo-LVOT area, indexed neo-LVOT area, and valve to septum distance were all significantly associated with LVOTO. Conclusions: The systolic mean LVOT area, neo-LVOT area, indexed neo-LVOT, expected percentage LVOT area reduction, and the valve to septum distance were associated with LVOTO after valve-in-MAC.
تدمد: 1941-7632
1941-7640
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::4d4b043e7fb34d25a498faed8b56378f
https://doi.org/10.1161/circinterventions.121.010854
رقم الأكسشن: edsair.doi.dedup.....4d4b043e7fb34d25a498faed8b56378f
قاعدة البيانات: OpenAIRE