Effects of preoperative intentional hemodilution on the extravasation rate of albumin and fluid

التفاصيل البيبلوغرافية
العنوان: Effects of preoperative intentional hemodilution on the extravasation rate of albumin and fluid
المؤلفون: Michel Comet, Jean François Payen, C. Jacquot, Paul Stieglitz, Jean Philippe Vuillez, Jean Luc Lafond, Bruno Geoffray
المصدر: Critical care medicine. 25(2)
سنة النشر: 1997
مصطلحات موضوعية: Oncotic pressure, Adult, Male, medicine.medical_specialty, Randomization, Adolescent, Blood Pressure, Hematocrit, Critical Care and Intensive Care Medicine, Intensive care, Extracellular fluid, Preoperative Care, medicine, Electric Impedance, Humans, Prospective Studies, Serum Albumin, Hemodilution, medicine.diagnostic_test, business.industry, Albumin, Extravasation, Surgery, Anesthesia, Female, business, Perfusion, Extravasation of Diagnostic and Therapeutic Materials
الوصف: To evaluate the effects of preoperative intentional hemodilution with 4% albumin solution on the extravasation rate of intravascular albumin and fluid in surgical patients.A prospective, randomized, clinical study.University teaching hospital.Two groups (control group [group 1] and hemodiluted group [group 2]) of 13 healthy patients were studied during a long-term (4 hrs) surgical procedure.Autologous technetium-99m (99mTc)-labeled red blood cells and indium-oxine ((111)In)-labeled human serum albumin were injected intravenously during anesthesia at T = 0 min in the two groups for the determination of total blood volume and albumin diffusion space, respectively. In addition, body tetrapolar electrical impedance was used to assess extracellular fluid volume. In the hemodiluted group (group 2), 15 mL/kg of blood was withdrawn over 30 mins (T = 20 mins to T = 50 mins) and simultaneously replaced by an equal volume of 4% albumin solution (0.6 g/kg).The albumin diffusion space, the colloid oncotic pressure, the plasma albumin concentration and the electrical impedance were measured before (T = 10 mins) and after (T = 60, 120, and 240 mins) hemodilution. Urine was collected from T = 10 mins to T = 240 mins. The total blood volume was calculated at T = 10 mins. No differences in the initial values were found between the two groups. In group 2, hemodilution (hematocrit 30 +/- 3%) resulted in a steeper increase in the albumin diffusion space (p.05) and a progressive decrease in the body electrical impedance (p.05). The extravasation rate of albumin was 0.052 +/- 0.007 mL/kg/min in group 2 vs. 0.038 +/- 0.020 mL/kg/min in group 1 (p.05). The value of calculated plasma volume at T = 0 min did not shown any difference between the two groups. This value was then lower than expected in group 2, corresponding to a loss of plasma volume of3 mL/kg. Urine output was significantly lower in group 2 than in group 1 (0.7 +/- 0.4 vs. 1.4 +/- 1.0 mL/min, respectively; p.05). A comparable decrease in colloid oncotic pressure and in plasma albumin concentration was observed in both groups.These results suggest that preoperative hemodilution using 4% albumin on a 1:1 volume basis for blood substitution during a prolonged surgical procedure with reduced blood losses enhances the extravasation rate of albumin and fluid to the interstitial tissues, impeding the maintenance of isovolemia. These findings support the use of a volume of infused colloid solution higher than that of withdrawn blood during preoperative hemodilution.
تدمد: 0090-3493
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::4f5fc74eb3f21b0ee3c007543f159eea
https://pubmed.ncbi.nlm.nih.gov/9034258
رقم الأكسشن: edsair.doi.dedup.....4f5fc74eb3f21b0ee3c007543f159eea
قاعدة البيانات: OpenAIRE