An optimized fluorogenic ADAMTS13 assay with increased sensitivity for the investigation of patients with thrombotic thrombocytopenic purpura

التفاصيل البيبلوغرافية
العنوان: An optimized fluorogenic ADAMTS13 assay with increased sensitivity for the investigation of patients with thrombotic thrombocytopenic purpura
المؤلفون: Joshua Muia, Jian Zhu, S. C. Covill, L. Dolatshahi, Sandra L. Haberichter, Weiqiang Gao, Kenneth D. Friedman, J E Sadler, Lisa A. Westfield
المصدر: Journal of thrombosis and haemostasis : JTH. 11(8)
سنة النشر: 2013
مصطلحات موضوعية: Male, medicine.medical_specialty, Bilirubin, Recombinant Fusion Proteins, Thrombotic thrombocytopenic purpura, ADAMTS13 Protein, Sensitivity and Specificity, Article, Substrate Specificity, chemistry.chemical_compound, Von Willebrand factor, Internal medicine, von Willebrand Factor, medicine, Humans, Fluorescent Dyes, Chromatography, biology, Purpura, Thrombotic Thrombocytopenic, Thrombotic Microangiopathies, Barium chloride, Anticoagulants, Reproducibility of Results, Hematology, medicine.disease, Blood proteins, Thrombocytopenia, Low ionic strength, ADAMTS13, ADAM Proteins, Endocrinology, chemistry, Case-Control Studies, Mutation, biology.protein, Female, Hemoglobin, Peptides, Plasmids
الوصف: Most ADAMTS13 assays use non-physiological conditions (low ionic strength, low pH, barium chloride), are subject to interference from plasma proteins, hemoglobin and bilirubin, and have limited sensitivity, especially for inhibitors.We addressed these constraints by designing a substrate that can be used in undiluted plasma.A polypeptide was expressed in E. coli that corresponds to von Willebrand factor Gln(1599) -Arg(1668) , with mutations N1610C and K1617R and an N-terminal Gly. Substrate FRETS-rVWF71 was prepared by modifying Cys(1610) with DyLight 633 (abs 638 nm, em 658 nm) and the N-terminus with IRDye QC-1 (abs 500-800 nm). Assays were performed at pH 7.4 in 150 mm NaCl, 10 mm CaCl2 .Serum and plasma anticoagulated with citrate or heparin had equivalent ADAMTS13 activity with FRETS-rVWF71. Neither bilirubin (≤ 20 mg dL(-1) ) nor hemoglobin (≤ 20 g L(-1) ) interfered with product detection. Assays with FRETS-rVWF71 and FRETS-VWF73 gave similar results (R(2 ) = 0.95) for plasma from 80 subjects with thrombotic microangiopathy, 22 subjects with other causes of thrombocytopenia, and 20 healthy controls. The limit of detection with FRETS-rVWF71 for ADAMTS13 activity was ≤ 0.3%. Inhibitor assays with FRETS-rVWF71 gave titers ~2.5-fold higher than with FRETS-VWF73 and clearly distinguished patients with and without inhibitors.FRETS-rVWF71 is suitable for ADAMTS13 assays in minimally diluted plasma or serum without interference from proteins, bilirubin or free hemoglobin in plasma. Optimized detection of ADAMTS13 inhibitors will facilitate the monitoring of antibody responses during the treatment of thrombotic thrombocytopenic purpura.
تدمد: 1538-7836
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::50745b3a39081e8a9039af1dfefeb055
https://pubmed.ncbi.nlm.nih.gov/23773695
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....50745b3a39081e8a9039af1dfefeb055
قاعدة البيانات: OpenAIRE