A Comparative Evaluation of the Dimensional Accuracy of Heat Polymerized Acrylic Resin Denture Base Clamped by the Conventional Method and by New-press Technique and Cured by Long Curing Cycle: An in vitro Study

التفاصيل البيبلوغرافية
العنوان: A Comparative Evaluation of the Dimensional Accuracy of Heat Polymerized Acrylic Resin Denture Base Clamped by the Conventional Method and by New-press Technique and Cured by Long Curing Cycle: An in vitro Study
المؤلفون: Ahmed St, Vinod, Gowd S, Goud Mv, Thatapudi Shankar, Rao Nv
المصدر: The Journal of Contemporary Dental Practice. 13:842-849
بيانات النشر: Jaypee Brothers Medical Publishing, 2012.
سنة النشر: 2012
مصطلحات موضوعية: Denture Bases, Hot Temperature, Time Factors, Materials science, Thermoplastic, Surface Properties, Acrylic Resins, Gingiva, Polymerization, Comparative evaluation, Dental Materials, Dental Arch, Materials Testing, Polymer chemistry, Maxilla, Humans, Jaw, Edentulous, In vitro study, Composite material, General Dentistry, Acrylic resin, Curing (chemistry), chemistry.chemical_classification, Dental Casting Technique, Temperature, Clamping, chemistry, visual_art, visual_art.visual_art_medium, Denture base, Plastics
الوصف: Aim The aim of this study is to evaluate the dimensional accuracy of heat polymerized acrylic resin denture base clamped by the conventional method and by new-press technique and cured by long curing cycle. Materials and methods In this study, a total of 60 standardized maxillary record bases were fabricated with seven reference points as follows: • Point A Incisive papilla, • Point B and C Canine region on either side • Point E and G Midpoint of tuberosities on either side • Point F Midpoint of the line joining the two tuberosities • Point D Midpoint between the line joining A and F Group A Ten maxillary record bases were fabricated by conventional clamping method and cured by long curing cycle. Group A’ Ten maxillary record bases were fabricated by New Press or RS tension clamping method and cured by long curing cycle. The distances between the reference points, i.e. A-B, A-C, A-D, D-F, B-E, C-G, E-F, F-G, B-D, D-G, C-D, D-E of all three thermoplastic denture base plates were measured and recorded with the help of travelling microscope and were used for comparison with the measured and recorded readings of processed acrylic denture bases. The data obtained was analyzed by using the one-way analysis of variance and HSD Multiple Comparison Test. Results The overall results of the study indicate that among all the denture bases cured by the two clamping systems and the long curing cycle, group A‘ were the most dimensionally stable, followed by control group A. Conclusion The study concluded that the denture bases fabricated by the New Press method using the long curing cycle would produce the most dimensionally stable denture bases. How to cite this article Shankar T, Gowd S, Ahmed ST, Vinod V, Goud MV, Rao NV. A Comparative Evaluation of the Dimensional Accuracy of Heat Polymerized Acrylic Resin Denture Base Clamped by the Conventional Method and by New-press Technique and Cured by Long Curing Cycle: An in vitro Study. J Contemp Dent Pract 2012;13(6):842-849.
تدمد: 1526-3711
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::535e8ede794b51890f8d0994eeed3b21
https://doi.org/10.5005/jp-journals-10024-1240
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....535e8ede794b51890f8d0994eeed3b21
قاعدة البيانات: OpenAIRE